Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-1122-00191
Parcel: 10818003B

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1

Permit Number - TC-COM-1122-00191
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/23/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
01/23/2023 Commercial Plumbing REQUIRES RESUBMIT The replacement of existing water heaters with new water heaters with twice the natural gas demand is not a repair. Provide a plumbing design performed by an Arizona registrant. Reference: Sections 107.1 and 107.2.1, IBC 2018.
12/17/2022 PDSD Application Completeness REVIEW COMPLETED