Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1122-00155
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/06/2023 | Historic | APPROVED | |||
01/23/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
01/23/2023 | External Reviewers - Stantec | REQUIRES RESUBMIT | City of Tucson Permit Number: TC-COM-1122-00155 Stantec Project Number: 185215066 Stantec File Number: TUC-23-008 ARCHITECTURAL COMMENTS Sheet A0.0 1. Note on the cover of the drawings that special inspection is required for cast-in-place anchor bolts. Also, provide City of Tucson special inspection certificate(s) with Parts A and B completed. Make sure that the owner or their legal representative signs the form. 2. Please indicate on the plans that the kitchen hood suppression system [2018 IBC Sec. 904.12] is to be provided as part of this project and is to be submitted as a separate permit (not a deferred submittal). 3. The code analysis is incomplete. The code analysis only addresses the existing structure, which is being converted to a restaurant; so where is the information regarding the detached canopy? Size (square feet), construction type, allowable area, occupancy group, etc. all need to be communicated. 4. The code analysis indicates this as a Group B Occupancy, however with the combined area and occupancy of the existing building and detached dining canopy this is actually a Group A-2 Occupancy per 2018 IBC Sec. 303.1.1 and 303.1.2. Sheet A2.1 1. Please clarify on the plans that there is a vertical grab bar next to the existing ADA toilet in the existing restroom and that all other ADA requirements have been met. STRUCTURAL COMMENTS There are no comments. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Joel Svoboda, RA Senior Associate 520-545-7415 joel.svoboda@stantec.com |
||
01/03/2023 | Site Engineering | REQUIRES RESUBMIT | The DP needs to be approved before the building plans can be approved. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
||
12/12/2022 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-1122-00155 733 S Stone Ave – HC-3 Food Service TRANSMITTAL: December 12, 2022 This site is located in the HC-3 zone (UDC 4.7.22). 1. Until DP21-0171 is approved by all review agencies Zoning cannot approve this plan. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
01/04/2023 | Fire New Construction | REVIEW COMPLETED | |||
12/08/2022 | PDSD Application Completeness | REVIEW COMPLETED |