Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-1122-00103
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/01/2022 Commercial Electrical APPROVED
01/30/2023 Commercial Structural APPROVED
11/28/2022 Site Zoning APPROVED
12/09/2022 Site Engineering NOT REQUIRED
01/30/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
01/03/2023 Commercial Mechanical REQUIRES RESUBMIT Footnote b on Table 403.3.1.1, IMC 2018 states that mechanical exhaust is required for the beauty salon and no air from the salon may be recirculated to any other space. FC-1 appears to be recirculating air from the salon area (335 square feet) to the remaining 728 square feet of the suite. Reference: Section 403.2.1 (3), IMC 2018.
01/03/2023 Commercial Plumbing REQUIRES RESUBMIT Verify that the distance from the hot water source to the hot water termination for the public lavatory complies with the requirements of Section C404.5, IECC 2018.
12/22/2022 Fire New Construction REVIEW COMPLETED
11/23/2022 PDSD Application Completeness REVIEW COMPLETED