Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1122-00082
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/23/2022 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
12/23/2022 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-1122-00082 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: CONDITIONALLY APPROVED Approved with the following Comments: 1. Drawings marked "good for construction" needs to be stamped with building permit approval, submitted documents are marked "not for construction". 2. Structural engineer needs to ensure before placement of footings for the new canopy that the new footing base is not encroaching into the load transfer area of the footings base of existing foundations. 3. Even though the design is based on 103 mph wind speed which is less than the design wind speed of 105 mph, design is acceptable as enough demand capacity ratio is available structurally and hence a revision to the structural design is not considered deemed necessary. 4. Erection drawings for the canopy complete with connection details have not been provided at this review stage, their submission can be considered a Deferred submittal and those details can be provided later for review and approval. BUILDING REVIEW COMMENTS: APPROVED MECHANICAL REVIEW COMMENTS: CONDITIONALLY APPROVED Approved/subject to field approval ELECTRICAL REVIEW COMMENTS DENIED E2.01 CONSTRUCTION PLAN - LIGHTING PHOTOMETRICS: Need to provide outdoor lighting power density calculations to prove compliance with 2018 IECC and PC/COT. PLUMBING REVIEW COMMENTS: DENIED First Plumbing Review 1). Plan set needs to include gutter & downspout sizes/calculations to plan page 48 -IPC 1106.3, 1106.6 If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
12/09/2022 | Site Engineering | REQUIRES RESUBMIT | The combo permit cannot be approved until its associated development package (TD-DEV-1122-00023) has been approved. | ||
11/23/2022 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-1122-00082 Canopy Additions (1st Review) 775 W Silverlake Rd - I-1 TRANSMITTAL DATE: November 23, 2022 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in I-1 Zone (UDC 4.7.29). Transportation Service Land Carrier is a permitted use (UDC Table 4.8-5), subject to Use Specific Standards 4.9.13.Q. A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The DP is a separate submittal from the building plans and is submitted at: https://docs.tucsonaz.gov/Forms/tucsonpermitapp, using Submission Type “Site Review”. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
12/04/2022 | Fire New Construction | REVIEW COMPLETED | |||
11/21/2022 | PDSD Application Completeness | REVIEW COMPLETED |