Permit Number: TC-COM-1122-00044
Parcel: 141185990

Review Status: Requires Resubmit

Review Details: BUILDING DEFERRED SUBMITTAL REVIEW v.1

Permit Number - TC-COM-1122-00044
Review Name: BUILDING DEFERRED SUBMITTAL REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/22/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/22/2025 External Reviewers - Stantec Express REQUIRES RESUBMIT Storefront Designs April 22, 2025
1st Review

Centennial American Properties
Attn: Jason Tankersley
1200 East Morehead, Suite 280
Charlotte, North Carolina 28204

Re: CAP STORAGE – OLD VAIL
NEW BUILDING (DEFERRED SUBMITTAL: STOREFRONT, STEEL FRAMING, STAIRS)

City of Tucson Permit Number: TC-COM-1122-00044
Stantec Project Number: 185215066
Stantec File Number: TUC-25-049

Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken.

The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

Occupancy
Group Construction
Type Area
(Square feet) Occupant
Load Automatic
Fire Sprinklers Fire
Alarms
S-1 II-B 105,504 240 Yes No
Separate Permits: Automatic fire sprinklers and signage.
Deferred Submittals: Metal stairs, storefront and window system, elevator shop drawings, prefabricated canopy
Special Inspections: Earthwork, concrete, epoxy and expansion anchors, structural steel, high-strength bolts, field welding, and masonry.

ARCHITECTURAL COMMENTS

General

1. The storefront, steel framing, and stair shop drawings require corrections to be made as noted by the architect and engineer of record. Please have the shop drawings revised with the noted corrections and resubmit them to the architect/engineer of record for rereview of compliance with the original design. Once reviewed please resubmit. [Ref. IBC 2018 Sec. 107.3.4.1]

STRUCTURAL COMMENTS

There are no comments.

MECHANICAL COMMENTS

There are no comments.

PLUMBING COMMENTS

There are no comments.

ELECTRICAL COMMENTS

There are no comments.


Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline.

Plans reviewed by:
Trevor Bies,
Senior Plan Reviewer
602-338-9922
trevor.bies@stantec.com
04/22/2025 External Reviewers - Stantec Express REQUIRES RESUBMIT Structural Steel Shop Drawings April 22, 2025
1st Review

Centennial American Properties
Attn: Jason Tankersley
1200 East Morehead, Suite 280
Charlotte, North Carolina 28204

Re: CAP STORAGE – OLD VAIL
NEW BUILDING (DEFERRED SUBMITTAL: STOREFRONT, STEEL FRAMING, STAIRS)

City of Tucson Permit Number: TC-COM-1122-00044
Stantec Project Number: 185215066
Stantec File Number: TUC-25-049

Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken.

The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

Occupancy
Group Construction
Type Area
(Square feet) Occupant
Load Automatic
Fire Sprinklers Fire
Alarms
S-1 II-B 105,504 240 Yes No
Separate Permits: Automatic fire sprinklers and signage.
Deferred Submittals: Metal stairs, storefront and window system, elevator shop drawings, prefabricated canopy
Special Inspections: Earthwork, concrete, epoxy and expansion anchors, structural steel, high-strength bolts, field welding, and masonry.

ARCHITECTURAL COMMENTS

General

1. The storefront, steel framing, and stair shop drawings require corrections to be made as noted by the architect and engineer of record. Please have the shop drawings revised with the noted corrections and resubmit them to the architect/engineer of record for rereview of compliance with the original design. Once reviewed please resubmit. [Ref. IBC 2018 Sec. 107.3.4.1]

STRUCTURAL COMMENTS

There are no comments.

MECHANICAL COMMENTS

There are no comments.

PLUMBING COMMENTS

There are no comments.

ELECTRICAL COMMENTS

There are no comments.


Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline.

Plans reviewed by:
Trevor Bies,
Senior Plan Reviewer
602-338-9922
trevor.bies@stantec.com
04/18/2025 PDSD Application Completeness Express REVIEW COMPLETED