Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-1026-01724
Parcel: 10703141E

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-1026-01724
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/09/2026 Commercial Electrical Standard APPROVED
11/16/2026 Commercial Mechanical Standard APPROVED
11/16/2026 Commercial Plumbing Standard APPROVED
11/16/2026 Site Zoning Standard APPROVED Refer to TC-COM-1026-01722
11/16/2026 Water - PDSD Standard APPROVED
11/09/2026 Outdoor Lighting Standard NOT REQUIRED No modifications to the outdoor lighting.
10/29/2026 Site Engineering Standard NOT REQUIRED
11/16/2026 Commercial Post Review Express PENDING ASSIGNMENT
11/16/2026 Commercial Building Standard REQUIRES RESUBMIT Please submit a complete set of revised/corrected documents and a written response addressing each review comment and explaining how it was resolved. The original submittal was incomplete, and additional comments may be issued upon subsequent review.
Please email me with any questions regarding the comments below: mark.masek@tucsonaz.gov
1. Please ensure the permit numbers, suite numbers are coordinated in the code analysis. IBC 107.2.1 For example, currently
TC-COM-1026-01722 is for suite 110 and listed as 12,000 sf on the plans and 9000sf in the permit details.
TC-COM-1026-01723 is for suite 150 and appears correct.
TC-COM-1026-01724 is for suite 180 and appears correct.
2. Please clarify the intended use of the area identified as "Warehouse" on the floor plans. The plans identify the occupancy as Group F-1; however, warehouse and storage uses are generally classified as Group S-1 or S-2, depending on the materials being stored.
Revise the plans to accurately identify the intended use and corresponding occupancy classification. If the area is intended for manufacturing, processing, or other factory industrial operations, provide a description of the activities performed to substantiate the Group F-1 classification. If the area is intended primarily for storage, revise the occupancy classification accordingly.
3. Please provide the use, number of occupants, the occupant load factor and ensure the occupant load factor reflects the use/function of the space. IBC 107.2.3, 1004.5
4. Please provide the total occupant load after above clarification has been addressed IBC 107.2.1
5. Please amend plans to show how the accessibility elements have been upgraded. IEBC 306.7.1 requires that accessibility be provided to the altered spaces. (Change of Occupancy is treated as an alteration In the IEBC0 Where the existing path of travel elements, which entails a primary entrance, a primary path of travel, sanitary facilities serving the area, a drinking fountain, and signs. If these items are not fully compliant, upgrades shall be required in accordance with IEBC.306.7.1. For example, the existing toilet rooms do not appear to have the required 5' foot clear floor space, not do they appear to have grab bars.
A. If the cost of providing or upgrading the items above to be accessible is disproportionate to the cost of construction (exceeds 20% of the cost of construction not including accessibility upgrades), please provide information to verify construction costs. If this exemption is taken, accessibility upgrades equaling 20% of the cost of the project shall be made, , or the space is fully accessible, whichever is less.
Please contact me if you have any questions about the above comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
11/13/2026 Fire New Construction Standard REVIEW COMPLETED
10/23/2026 PDSD Application Completeness Express REVIEW COMPLETED Master permit is TC-COM-1026-01722 and the Bluebeam session is 781-182-322 .