Permit Review Detail
Review Status: In Review
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1026-01673
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/30/2026 | Commercial Plumbing Standard | NOT REQUIRED | |||
| 10/30/2026 | Outdoor Lighting Standard | NOT REQUIRED | No modifications to the outdoor lighting. | ||
| 10/20/2026 | Site Engineering Standard | NOT REQUIRED | |||
| 10/30/2026 | Water - PDSD Standard | NOT REQUIRED | |||
| N/A | Commercial Building Standard | PENDING ASSIGNMENT | |||
| N/A | Commercial Post Review Express | PENDING ASSIGNMENT | |||
| N/A | Fire New Construction Standard | PENDING ASSIGNMENT | |||
| N/A | Site Zoning Standard | PENDING ASSIGNMENT | |||
| 10/30/2026 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-1026-01673 (5210 E WILLIAMS CI Unit:UNIT 500 TUCSON, AZ 85711) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Reference sheet A1.0, Floorplan Keynotes #2, and Sheet A2.0, Wall Tag C. Sheet A1.0 shows this wall as existing, but Sheet A2.0 shows this as a new wall with new construction details. Provide consistent information on the provided plans. 2. Provide as-built and updated electrical sheets, showing existing electrical and any new electrical associated with the relocated door and new demising wall. 3. If the new demising wall is a fire rated wall, show any electrical penetrations as properly rated and listed for use in a rated wall. 4. Provide an electrical panel schedule and designate the circuit number on the electrical plans, that corresponds to the panel schedule, at the location of each, new or modified light fixture, receptacle, and equipment disconnect switch, NEC arts;300 and 408.4. IBC 107.1. 5. Provide electrical load calculations, for the Main Service Panel, Per NEC 220.40. 6. Provide a line diagram showing the new equipment being added or modified, NEC 110.2, 2018 IBC 107.1. 7. Show all wiring methods in detail for all new or modified branch circuit conductors and feeders. Conductor type and conduit size/type. Note wet use requirements. NEC arts;300 and 408.4. |
||
| 10/30/2026 | Commercial Mechanical Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-1026-01673 ADDRESS/PARCEL: 5210 E WILLIAMS CI Unit:UNIT 500 TUCSON, AZ 85711 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov COMMENTS: 1. Please clarify whether any existing supply or return-air registers or associated ductwork are being relocated or modified due to the new demising wall. If so, provide a reflected ceiling plan showing the proposed changes. Reference: Section 107.2.1, IBC 2024. |
||
| 10/16/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |