Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-1026-01669
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/21/2026 | Commercial Electrical | NOT REQUIRED | |||
| 10/26/2026 | Commercial Mechanical | NOT REQUIRED | |||
| 10/26/2026 | Commercial Plumbing | NOT REQUIRED | |||
| 10/15/2026 | Site Engineering | NOT REQUIRED | |||
| 10/26/2026 | Site Zoning | NOT REQUIRED | |||
| 10/26/2026 | Water - PDSD | NOT REQUIRED | |||
| 10/29/2026 | Commercial Post Review Express | PENDING ASSIGNMENT | |||
| 10/27/2026 | Commercial Building | REQUIRES RESUBMIT | Please submit a complete set of revised/corrected documents and a written response addressing each review comment and explaining how it was resolved. Please note that the original submittal was incomplete, and the review was based on the information provided. Additional comments may be issued upon subsequent review. Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov Provide a Damage Assessment and Code-Compliant Construction Repair Plans 1. Submit a damage assessment and complete construction repair plans prepared, signed, dated, and sealed by an Arizona-registered design professional, as applicable to the scope of work. The submittal shall include the following: A. Identify Damaged Areas: Clearly identify and label all damaged areas on the site plan, floor plan, and applicable construction drawings. Cloud or otherwise delineate the affected areas. B. Document Damage and Proposed Repairs: Provide a detailed assessment of the extent of damage and specify the proposed repairs necessary to restore the affected areas to code compliance. Identify all affected building components and systems, including, as applicable, walls, ceilings, structural framing, electrical, plumbing, and mechanical systems. Specify the repair methods and replacement materials for each component. Clearly identify like-for-like repairs and indicate any components or systems evaluated and determined to be undamaged. C. Provide Complete Repair Plans: Submit complete architectural and structural construction drawings, as applicable, that address each area of damage and each proposed repair identified in the damage assessment. Clearly locate all repairs on the drawings and provide sufficient construction details to demonstrate compliance with applicable codes. Provide structural calculations if structural design is required. References: Arizona Revised Statutes § 32-125; Arizona Board of Technical Registration Rules R4-30-304; 2024 IBC Section 107.2.1; City of Tucson Commercial Plan Submittal Requirements. Please contact me if you have any questions about the above comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 10/29/2026 | Fire New Construction | REQUIRES RESUBMIT | Resolve building review comments. Questions: patricia.shelton@tucsonaz.gov |
||
| 10/15/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |