Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-1026-01635
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/21/2026 | Commercial Electrical | APPROVED | |||
| 10/21/2026 | Commercial Mechanical | APPROVED | |||
| 10/21/2026 | Commercial Plumbing | APPROVED | |||
| 10/21/2026 | Site Zoning | APPROVED | |||
| 10/07/2026 | Site Engineering | NOT REQUIRED | |||
| 10/20/2026 | Water - PDSD | NOT REQUIRED | |||
| 10/21/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/21/2026 | Commercial Building | REQUIRES RESUBMIT | October 20, 2026 1st Review Intertech Architectural Interiors Attn: Erin Hastreiter 6089 E. Grant Road Tucson, Arizona 85712 Re: LJA STORAGE ROOM TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-1026-01635 Stantec Project Number: 185215066 Stantec File Number: TUC-26-058 Plan review for the project referenced above has been completed. This letter reflects comments to be addressed. PLEASE send all responses to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B II-A 142 1 Yes No Separate Permits: Automatic fire sprinklers. Deferred Submittals: None. Special Inspections: None. ARCHITECTURAL COMMENTS Sheet A1 1. It appears that a plumbing shaft has been chopped through to add a door. The two open ends of the shaft have been infilled with a “new partition” (i.e. Keyed Note 1). First, the wall infills are not hatched per the legend. Second, suspect that this shaft is a fire-rated shaft designed to meet 2024 IBC Sec. 713, and as a 6 story building the fire rating of the shaft is 2-hours. Third, how are you maintaining the shaft horizontally over the new door? Please clarify on the plans. STRUCTURAL COMMENTS There are no comments. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Joel Svoboda, RA Senior Associate 520-545-7415 joel.svoboda@stantec.com |
||
| 10/21/2026 | Fire New Construction | REVIEW COMPLETED | |||
| 10/07/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |