Permit Number: TC-COM-1025-01955
Parcel: 116161310

Address:
849 N ANITA AV

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-1025-01955
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/19/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/19/2025 Commercial Building Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-1025-01955
ADDRESS/PARCEL: (849 N ANITA AV TUCSON, AZ 85705)

COMMENTS:
1. Please provide a Site Plan.
a. Please locate and label the location of the porch.
2. Ledger Detail Drawing
a. What is the existing building exterior wall made of.
i. Provide this information on the Section drawing.
b. Provide a detail drawing at the ledger.
i. Ensure to include the flashing detail.
ii. Should the exterior wall be made of EIFS or stucco, ensure the ledger have direct contact with the wall studs where the stucco is removed to allow this condition to occur.
iii. Show the pattern of the anchor bolts.
3. Post Beam Rafter detail drawing.
a. Provide a detail drawing whether saddle is used at the top of the post.
b. Please provide information complying to the code required continuous connection from rafter all the way to the footing.
4. Bottom of post detail drawing.
a. How is the Simpson Post Base installed.
i. Is epoxy used to secure the post base into concrete. (NOTE: Special inspection is required for post installed epoxy anchors.)
b. The bottom of the footing is required to be 12 inches below the top of native soil per IBC 1809.4.
i. The section drawing shows a few inches below grade top.
c. Is it best to pour a new concrete footing against the front face of the existing slab to resolve the issues above?
i. Please provide a detail drawing that will be code compliant.
5. Gutter
a. Gutter is identified within the Section drawing.
b. There is not downspout and splash pad shown on the drawing.
c. Please provide the above information onto the drawings.
6. Please resubmit.

Should you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976.
11/07/2025 Site Engineering Standard REQUIRES RESUBMIT Permit: TC-COM-1025-01955
Location: 849 N ANITA AV
Review Date: 11/7/2025
Site Engineering Comments:
1. Provide a supplemental site plan that is dimensioned to demonstrate exactly where on the site the proposed work will be occurring.
If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
11/17/2025 Site Zoning Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM:
Bobby Parsons
Zoning Review Section

PROJECT:
TC-COM-1025-01955
849 N. Anita Ave. Tucson, AZ 85705
Demolish and rebuild existing porch to code (1st Review)

TRANSMITTAL DATE: 11/17/2025

This site is located in the R-3 zone (UDC 4.7.12).

Comment: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: Please provide an accurately dimensioned site plan to show exactly where the proposed work will occur.
2. Comment: Additional comments may be forthcoming based on responses to zoning comments and plans submitted.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
11/19/2025 Fire New Construction Standard REVIEW COMPLETED
10/31/2025 PDSD Application Completeness Express REVIEW COMPLETED