Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-1025-01932
Parcel: 14118008P

Review Status: Requires Resubmit

Review Details: COMMERCIAL FENCE/WALL v.1

Permit Number - TC-COM-1025-01932
Review Name: COMMERCIAL FENCE/WALL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/06/2025 Commercial Building NOT REQUIRED Zoning ONLY permit.
11/07/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/31/2025 Site Engineering REQUIRES RESUBMIT Permit: TC-COM-1025-01932
Location: 10042 E OLD VAIL RD
Review Date: 10/31/2025
Site Engineering Comments:
1. It will be required that a fully dimensioned site plan be submitted for this development as it can be considered minimal site work. It would be possible to use previous site plans with added fence details that were used for the submission of DP21-0263. This will include an overview of the site as a whole and carry with it all necessary dimensions to ensure full compliance.
If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
11/07/2025 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM:
Bobby Parsons
Zoning Section Review

PROJECT:
TC-COM-1025-01932
10042 E. Old Vail Rd. Tucson, AZ 85747
New fence and gates (1st Review)

TRANSMITTAL DATE: 11/7/2025

This site is located in the PAD-36 (Houghton Town Center Pad).

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: The proposed fence is being placed over the pedestrian circulation path and was not shown on the previously issued development package. Per Technical Standards 7-01.4.1.B, a sidewalk is required adjacent and parallel to any access lane or PAAL on the side where the building is located. As the proposed fence is altering the pedestrian circulation and doesn’t meet TSM 7-01.4.1, a development package will be required. Per UDC Article 3.3.3.G.2.c, a site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A Development Package (DP) meeting the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites is required to be submitted and approved. The DP is a separate submittal from the building plans. The checklist can be found at:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/minor_changes_to_commercial_industrial_sites_.pdf. Site zoning is unable to approve this building permit until the DP has been approved by all reviewers.
2. Comment: Additional comments may be forthcoming based on responses to zoning comments and plans submitted.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
10/21/2025 PDSD Application Completeness Express REVIEW COMPLETED