Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-1025-01884
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/05/2026 | Site Zoning Standard | APPROVED | |||
| 12/29/2025 | Water - PDSD Standard | APPROVED | |||
| 01/05/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/29/2025 | Commercial Mechanical Standard | REQUIRES RESUBMIT | 1. The minimum size of a condensate drain is ¾”, not ½” (shown on P1.1 and M-1.0) [Initial comment: Show the size, routing, and termination of the condensate drain for the heat pump. Reference: Section 307.2.1, IMC 2018 as amended by the City of Tucson.] 2. Secure the refrigerant lines from unauthorized access, not the electrical power, see Section 1101.10, IMC 2018. [Initial comment: Secure the refrigerant circuit access ports of the outside unit of the heat pump to prevent unauthorized access. Reference: Section 1101.10, IMC 2018.] |
||
| 12/29/2025 | Commercial Plumbing Standard | REQUIRES RESUBMIT | Comment not addressed. The 4” building drain has a 3” cleanout (see P1.0 and P-2.0). Note: The drain sizes shown on the plumbing plan and the “sewer diagram” are not coordinated. [Initial comment: Provide cleanouts that are the same size as the pipe that they serve. Reference: Section 708.1.5, IPC 2018.] | ||
| 12/30/2025 | Site Engineering Standard | REQUIRES RESUBMIT | Site Engineering can not approve this permit until TD-DEV-0424-00126 has been approved. | ||
| 12/09/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |