Permit Review Detail
Review Status: In Review
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1024-02075
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: In Review
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/13/2024 | Commercial Structural | APPROVED | |||
10/31/2024 | Fire New Construction | NOT REQUIRED | |||
N/A | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
N/A | Site Zoning | PENDING ASSIGNMENT | |||
11/07/2024 | Commercial Electrical | REQUIRES RESUBMIT | Permit Review TC-COM-1024-02075 (3350 E GRANT RD TUCSON, AZ 85716) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. Provide a Grounding Electrode System at the detached structures per NEC 690.47. 2. Show the Grounding Conductor’s connection at the modules, mounting and metal support structure. 3. Show grounding details for the mounting equipment and metal support frame, NEC690.43. Outdoor lighting Review: 4. Clarify if any additional under canopy lights are being added. 5. Provide circuiting information for any under-canopy lighting, including conductor, conduit, OCPD and circuit number. 6. Provide disconnect means as required per 225.31- 225.32 for the lighting circuits. 7. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. Show unshielded fixtures with a maximum of 3,000 lumens, OLC 401.4. 8. Full Cut Off fixtures under an overhang or canopy are exempt from the calculation, OLC 4.2.1. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
11/15/2024 | Site Engineering | REQUIRES RESUBMIT | TC-COM-1024-02075 3350 E GRANT RD Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The Administrative Manual can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes-and-Plans/Zoning-Code#section-1. Chris Arrington chris.arrington@tucsonaz.gov |
||
10/30/2024 | PDSD Application Completeness | REVIEW COMPLETED |