Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1024-02061
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/18/2024 | Site Engineering | APPROVED | |||
| 11/27/2024 | Site Zoning | APPROVED | |||
| 12/05/2024 | Water - PDSD | APPROVED | |||
| 12/05/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/13/2024 | Commercial Electrical | REQUIRES RESUBMIT | |||
| 11/13/2024 | Commercial Mechanical | REQUIRES RESUBMIT | 1. Sheet M2.00, 2018 IMC 504; Provide clothes dryer exhaust detail. DMA | ||
| 11/13/2024 | Commercial Plumbing | REQUIRES RESUBMIT | |||
| 11/13/2024 | Commercial Structural | REQUIRES RESUBMIT | Sheet c0.01; For questions regarding Plan Review comments please contact: Dino M. Accardo, MCP, CBO, E: daccardo@willdan.com. Fire Plan Review is NOT within the scope of this review. All applicable comments will be followed with the initials, DMA 1. Sheet C0.01, 2018 IBC 1107.6.2.2.1 Type A units. In Group R-2 occupancies containing more than 20 dwelling units or sleeping units, at least 2 percent but not less than one of the units shall be a Type A unit. ALL Group R-2 units on a SITE shall be considered to determine the total number of units and the required number of Type A units. Type A units shall be dispersed among the various classes of units. Provide Type A and B calculation and dispersion. DMA 2. Sheet C0.01; Provide window and door schedules on the plans. DMA 3. Sheet g0.07, 2018 IBC 714.2 Installation. A listed penetration firestop system shall be installed in accordance with the manufacturer’s installation instructions and the listing criteria. Provide on the plans the listing and installation instructions for firestop systems. DMA 4. Sheet as1.01, 2018 IBC Detail and dimension Fire-Separation distances for structures on the site and property lines. NOTE: Code data identifies structures proposed as R-2 in accordance with the 2018 IBC. DMA 5. Sheet S1.0, 2018 IBC Ch 17; Provide Tucson Special Inspection Certificate. DMA 6. Sheet S1.0; Submit referenced Saeco soils report for this review. DMA |
||
| 11/17/2024 | Fire New Construction | REVIEW COMPLETED | |||
| 11/01/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |