Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: In Review
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1024-02005
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: In Review
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
N/A | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
N/A | Site Zoning | PENDING ASSIGNMENT | SAME SET OF PLANS: TC-COM-0924-01796 (4515 E GRANT RD Unit:BLDG 7 UNIT 152) TC-COM-1024-02005 (4515 E GRANT RD Unit:BLDG 7 UNIT 151) | ||
N/A | Water - PDSD | PENDING ASSIGNMENT | SAME SET OF PLANS: TC-COM-0924-01796 (4515 E GRANT RD Unit:BLDG 7 UNIT 152) TC-COM-1024-02005 (4515 E GRANT RD Unit:BLDG 7 UNIT 151) | ||
10/28/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | SAME SET OF PLANS: TC-COM-0924-01796 (4515 E GRANT RD Unit:BLDG 7 UNIT 152) TC-COM-1024-02005 (4515 E GRANT RD Unit:BLDG 7 UNIT 151) Structural(S) Reviewer Kimiyoshi Shimabukuro kshimabukuro@safebuilt.com Denied Reason: Date Completed : 10/26/2024 5:14:03 PM 1. A1.0 – Existing and demolition plan use is unclear inside the screen panes and gate. Show the occupancy classification of this existing space. 2. A1.0 – MPE1.0 shows new plumbing fixtures but existing and demolition plan in A1.0 does not show any saw cuts if any for these. Keynote 6 states existing concrete slab to remain. Provide infill floor slab detail when applicable. 3. A1.0 – Show the existing slab slope if any and how it is compatible to be used as a residential floor. Existing concrete floor appears to have slope to drain. Provide explanation. 4. A1.0 - Provide scope of any special inspections and tests according to 2018 IBC chapter 17. Building(B) Reviewer Kimiyoshi Shimabukuro kshimabukuro@safebuilt.com Denied Reason: Date Completed : 10/26/2024 5:15:14 PM 1. Sheet C1.0 – Building 7 and building R are indicated making the scope unclear. Building R is shown in SP1.0 but not building 7. Clarify the scope per 2018 International Building Code section 107.2.1, Typ. 2. C1.0 - Flame spread class and index uses S-1 occupancy, but occupancy and use are shown as R2 – residential. 3. C1.0 – Fire alarm scope not mentioned. 4. C1.0 – Show the actual added habitable area (SF). 5. A1.1 – 1-hr fire rated demising wall doesn’t provide UL listed assembly number. 6. A1.1 – Note states “conditions noted are typical for three locations on the site with one location reversed (see site plan for locations). Show this scope in site plan SP1.0. 7. A2.0 – Show the exterior elevation in its entirety. C1.0 defines 2 story, 20-8” existing building but elevations and section only shows one story. 8. A3.0 – low profile no light ceiling fan is in used symbol but not represented in the RCP. Clarify scope Mechanical(M) Reviewer Kimiyoshi Shimabukuro kshimabukuro@safebuilt.com Denied Reason: Date Completed : 10/26/2024 5:14:42 PM 1. Sheet MEP1.0 – Ventilation calculation missing. 2018 International Mechanical Code section 402.2. The minimum openable area to the outdoors shall be 4 percent of the floor area being ventilated. 2. Provide energy compliance certificates such as COMcheck to demonstrate according to 2018 International Energy Conservation Code per Chapter 4 (Residential Energy Efficiency). Electrical(E) Reviewer Kimiyoshi Shimabukuro kshimabukuro@safebuilt.com Denied Reason: Date Completed : 10/26/2024 5:14:58 PM 1. Sheet MPE1.0 – GFCI per 2017 National Electrical Code section 210.8(A) unidentified. 2. MPE1.0 – AFCI not provided per 2017 NEC section 210.12(A). 3. MPE1.0 – Low profile no light ceiling fan is used in A3.0 symbols but described in new subpanel unit. 4. MPE1.0 – Fire rated wall detail shows 5/8” type ‘X’ gyp bd but A1.1 shows ½” type ‘X’ gyp bd. Coordinate details to clarify scope. 5. Provide energy compliance certificates such as COMcheck to demonstrate according to 2018 International Energy Conservation Code per Chapter 4 (Residential Energy Efficiency). Plumbing(P) Reviewer Kimiyoshi Shimabukuro kshimabukuro@safebuilt.com Denied Reason: Date Completed : 10/26/2024 5:14:25 PM 1. Sheet C1.0 – Plumbing fixture requirements doesn’t show number of dwelling units and provided automatic clothes washer with this addition per 2018 International Plumbing Code table 403.1. Show compliance added to existing washer. 2. SP1.0 – Show the location of central boiler. 3. MPE1.0 – ¾” CW note floating (untagged). 4. MPE1.0 – Missing sewer waste lines connecting to the new fixture. Also identify the connection to existing sewer line (s). 5. MPE1.0 – Missing plumbing fixture riser diagram. |
||
10/29/2024 | Fire New Construction | REQUIRES RESUBMIT | Resolve building comments. john.vincent@tucsonaz.gov 5203495581 SAME SET OF PLANS: TC-COM-0924-01796 (4515 E GRANT RD Unit:BLDG 7 UNIT 152) TC-COM-1024-02005 (4515 E GRANT RD Unit:BLDG 7 UNIT 151) |
||
11/07/2024 | Site Engineering | REQUIRES RESUBMIT | 1. This permit references building 7 but all of the building are labeled with letters. Clearly label the buildings and show where the units are located for each building permit. 2. The associated development package TD-DEV-0924-00252 must be approved before this permit can be approved. Mike Ortiz michael.ortiz@tucsonaz.gov |
||
10/24/2024 | PDSD Application Completeness | REVIEW COMPLETED |