Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-1024-01972
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/04/2024 | Commercial Mechanical | APPROVED | |||
11/06/2024 | Site Zoning | APPROVED | |||
10/30/2024 | Site Engineering | NOT REQUIRED | |||
11/06/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
10/30/2024 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Building Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. 1. Please amend the plan to indicate Furniture Store Expansion will require a permit and result in a new C of O. 2. Please amend plans to show required 10” Kick Plate 404.2.9 2009 ICC A117.1 A. Door surfaces within 10 inches of the floor, measured vertically, shall be a smooth surface on the push side extending the full width of the door. Cavities created by added kick plates shall be capped. 3. Please amend plans to show accessible service and sales counters on plans. IBC 107.2.1 and 2009 ICC A117.1 Chapter 9 4. Please amend plans to provide elevation detail of drinking fountain showing cane detectability or provide alcove to ensure drinking fountain is not a protruding object IBC1003.3 Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
10/31/2024 | Commercial Electrical | REQUIRES RESUBMIT | Please address the electrical plan review comments and provide a written response. 1 Provide complete compliance with the 2018 IECC for the lighting. |
||
11/04/2024 | Commercial Plumbing | REQUIRES RESUBMIT | 1. If the “beverage dispenser” is to be used in lieu of a drinking fountain, show the installation of a permanently mounted disposable cup dispenser. The cup dispenser shall be located adjacent to the water dispenser with the dispensing end between 34” and 48” above the finished floor. See: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/2008-21_e_drinkingfountainpolicy.pdf 2. Clarify how the distance from the hot water source to the hot water termination for the public lavatories complies with the requirements of Section C404.5, IECC 2018. |
||
10/31/2024 | Fire New Construction | REVIEW COMPLETED | |||
10/17/2024 | PDSD Application Completeness | REVIEW COMPLETED |