Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-1023-02560
Parcel: 135084450

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-1023-02560
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/19/2024 Commercial Structural APPROVED
01/19/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
01/09/2024 Commercial Electrical REQUIRES RESUBMIT PLEASE ADDRESS THE ELECTRICAL PLAN REVIEW COMMENTS AND PROVIDE A WRITTEN RESPONSE.

The electrical review comments are not completely addressed.

1. Previous review comment to “provide a detailed description in the electrical plans of the electrical scope of work proposed”, is not addressed.

1a. Is the being re-wired?

1b. Is all the lighting, switches, receptacles, electrical devices, mechanical, electrical water heater, being replaced?

1. The written response addresses review comments made by SafeBuilt. The review for this Activity was reviewed by the City of Tucson. Verify that the response letter is not intended for a different project.

2. The electrical line diagrams call out for the replacement of the 100 amp sub panel “Like for Like’, however the load calculations show a total panel load of 103 amps and the feeders to the sub panel are undersized, NEC art’s 215, 220. Provide a complete and accurate electrical line diagram from the electrical source to the sub-panel.

3. The panel schedule does not correlate with the electrical devices and equipment shown in the load calculations, NEC art 408.4.

4. Provide a complete electrical and lighting floor plan with plan notes showing in detail what exactly the scope of work involves, (What is existing to remain and what is new) and show branch circuit designations for all devices and plumbing/mechanical equipment as applicable that correlates with the panel schedule..

5. Provide complete luminaire schedule. Also address the 2018 IECC requirements for the lighting.

6. Provide compliance with the 2012 City of Tucson Outdoor Lighting Code if applicable.

Provide electrical design and calculations performed by an Arizona registrant who has demonstrated proficiency through registration, education, technical knowledge, or experience to perform such work.

Ref; 2018 IBC section 107.2.1, 2017 NEC, 2018 IECC, 2012 City of Tucson Outdoor Lighting Code, City of Tucson Commercial Plan Submittal Requirements.
12/21/2023 PDSD Application Completeness REVIEW COMPLETED