Review Date Reviewer's Name Type of Review Description Status Comments
12/28/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/28/2023 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Building(B) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 12/28/2023 4:44:58 PM
Pending the approval of the other trades.



Mechanical(M) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 12/28/2023 4:45:13 PM
Pending the approval of the other trades



Electrical(E) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 12/28/2023 4:44:15 PM
1) Unresolved - Sheet E.2 (Electrical Drawings): Show the GFCI protected receptacles for the kitchen, rooftop, exterior, and within 6ft of the sinks. (2017 NEC section 210.8(B)(2), (3), (4), and (5)) All kitchen single phase 150v and 50A or less and 3- phase 150V and 100A or less receptacles are required to be GFCI protected whether they serve countertop areas or not. All rooftop receptacles are to be GFCI protected. Please revise electrical details on sheet E.2.




Plumbing(P) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 12/28/2023 4:45:29 PM
Pending the approval of the other trades.