Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1023-02509
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/08/2023 | Site Zoning | APPROVED | |||
| 11/22/2023 | Water - PDSD | APPROVED | |||
| 11/22/2023 | Site Engineering | NOT REQUIRED | |||
| 11/22/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/02/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 11/2/2023 1:17:07 PM See the building review comments. Building(B) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 11/2/2023 1:15:25 PM 1) Sheet G.1 (Cover Sheet): Include a brief scope of work. (2018 IBC section 107) 2) Sheet A.1 (Floor Plans): Include the accessible toilet room component, fixture and clear floor and turning space details and dimensions. (2009 ICC A117.1 sections 304, 305, 603, 603.2.2, 604, 606) 3) Sheet P1.0 (Plumbing Drawings): All sinks, floor sinks, mops sink, hand wash sinks, floor drains, etc. listed in the amended 2018 IPC section 1003.3 are to be connected to the grease interceptor. Hand sinks not connected to the grease interceptor can include a sign specifying “HANDWASH SINK ONLY! NO FOOD PREPARATION OR DISHWASHING ALLOWED.” Please make revisions to all sheets and details. 4) Sheet E.2 (Electrical Drawings): Include the new or existing electrical service equipment details, main disconnect, one-line diagram, and show the required workspace dimensions for the equipment. (2017 NEC sections 110.26, 225.31, 225.32, 225.33) 5) Sheet E.2 (Electrical Drawings): Show the GFCI protected receptacles for the kitchen, rooftop, exterior, and within 6ft of the sinks. (2017 NEC section 210.8(B)(2), (3), (4), and (5)) Mechanical(M) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 11/2/2023 1:16:24 PM See the building review comments. Electrical(E) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 11/2/2023 1:15:55 PM See the building review comments. Plumbing(P) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 11/2/2023 1:16:45 PM See the building review comments |
||
| 11/20/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 10/30/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |