Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-1023-02383
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/02/2023 | Water - PDSD | APPROVED | |||
11/02/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
10/24/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 10/23/2023 5:14:09 PM See the building review comments. Building(B) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 10/23/2023 5:12:13 PM 1) Sheet G001 (Project Details): Include the allowed vs actual area, height, and number of stories per the 2018 IBC Chapter 5. 2) Sheets P101, 102, and P103 (Plumbing Details and Drawings): Hand sinks in kitchens are required to be connected to the grease interceptor or have a sign posted stating "HANDWASH SINK ONLY! NO FOOD PREPARATION OR DISHWASHING ALLOWED.” The hand sinks in the kitchen are not connected to the grease interceptor. If connecting the sinks to the grease trap, please revise the fixture calculations for the grease trap and revise all applicable sheets. (2018 IPC amended section 1003.3) 3) Sheets P101, 102, and P103 (Plumbing Details and Drawings): Hydromechanical grease interceptors are only allowed when there are 4 or fewer fixtures. Please revise all applicable sheets and calculations using the Gravity Grease Interceptors Table. (2018 IPC amended section 1003.3) Mechanical(M) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 10/23/2023 5:13:22 PM See the building review comments. Electrical(E) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 10/23/2023 5:12:57 PM See the building review comments. Plumbing(P) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 10/23/2023 5:13:43 PM See the building review comments. |
||
10/30/2023 | Site Engineering | REQUIRES RESUBMIT | See zoning comment | ||
10/26/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-1023-02383 9556 E. Golf Links Rd. – C-1 Food Service (1st Review) TRANSMITTAL: October 26, 2023 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in C-1 zone (UDC 4.7.20), Food Service: Excluding Soup Kitchens is a permitted use in the zone (UDC Table 4.8-4), subject to Use Specific Standards 4.9.4.M.1 & 5 and 4.9.13.O. 1. Zoning acknowledges that Development Package (DP) TD-DEV-1023-00411 has been submitted for this project but until at least one review is completed Zoning will not review the building plans for compliance with the DP. Zoning will review on the next submittal. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
10/24/2023 | Fire New Construction | REVIEW COMPLETED | |||
10/12/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |