Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-1023-02381
Parcel: 11452008H

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-1023-02381
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/30/2023 Site Engineering APPROVED
10/26/2023 Site Zoning APPROVED
10/23/2023 Fire New Construction NOT REQUIRED
10/30/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/18/2023 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Structural(S) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 10/17/2023 2:47:58 PM
See the building review comments



Building(B) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 10/17/2023 2:47:25 PM
1) Sheet S1.0 (Cover Sheet): Include the basic building details of the use group, construction type, occupancy, height, area, and number of each size of structure. (2018 IBC section 107)

2) Sheet S2.0 (Drawings): Specify the foundation type being used. Include the dimensions, area, and number of each size of structure. Show the specific locations of the footings and posts for each structure. Detail locations of columns around
handicap parking spaces. (2018 IBC section 107, 2009 ICC A117.1 section 502)



Mechanical N/A


Electrical N/A


Plumbing N/A
10/11/2023 PDSD Application Completeness Express REVIEW COMPLETED