Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1023-02381
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/30/2023 | Site Engineering | APPROVED | |||
| 10/26/2023 | Site Zoning | APPROVED | |||
| 10/23/2023 | Fire New Construction | NOT REQUIRED | |||
| 10/30/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/18/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 10/17/2023 2:47:58 PM See the building review comments Building(B) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 10/17/2023 2:47:25 PM 1) Sheet S1.0 (Cover Sheet): Include the basic building details of the use group, construction type, occupancy, height, area, and number of each size of structure. (2018 IBC section 107) 2) Sheet S2.0 (Drawings): Specify the foundation type being used. Include the dimensions, area, and number of each size of structure. Show the specific locations of the footings and posts for each structure. Detail locations of columns around handicap parking spaces. (2018 IBC section 107, 2009 ICC A117.1 section 502) Mechanical N/A Electrical N/A Plumbing N/A |
||
| 10/11/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |