Permit Number: TC-COM-1023-02360
Parcel: 11613195E

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-1023-02360
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/16/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
02/16/2024 Commercial Plumbing REQUIRES RESUBMIT Comment Letter addressing the plumbing comments was not received with this resubmittal and these comments are restated from the previous review.
1. Verify if an existing grease interceptor is currently in place to prevent the discharge of fats, oil, and grease into the public sewer. If a grease interceptor is not in place, show how the public sewer is to be protected from harmful discharges. Reference: Section 1003.1, IPC 2018. 2. Verify that water closets will not be draining through a grease interceptor. Reference: Sections 1003.2 and 1003.3.1, IPC 2018
Mark Masek
Plans Examiner
Mark.masek@tucsonaz.gov
520-837-4994
02/14/2024 Commercial Structural REQUIRES RESUBMIT Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.
1. Metered faucets shall remain open for 10 seconds minimum per 606.4, Water supply and drain pipes under lavatories shall be insulated to protect against contact per ANSI 606.6 3. Please add these notes in your drawings.
2. Restrooms: Other fixtures not allowed within the water closet clearance area per ANSI A117.1 figure 604.3. Please correct the restroom layouts on your Proposed Floor Plan,
3. Please resubmit.