Permit Number: TC-COM-1023-02359
Parcel: 14023104A

Address:
6090 S PARK AV

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-1023-02359
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/26/2023 Site Zoning APPROVED
11/02/2023 Water - PDSD APPROVED
10/30/2023 Site Engineering NOT REQUIRED
11/02/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/12/2023 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Structural(S) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 10/12/2023 1:23:21 PM
See the building review comments.




Building(B) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 10/12/2023 1:21:38 PM
1) General: Show the accessibility details and dimensions. (2009 ICC A117.1)

2) General: Include the details for the sprinkler system if installed or as a deferred submittal. (2018 IBC 107.1, 2018 IEBC section 106.1)

3) Sheets A-2 (Floor Plan), MP2.0 (Plumbing Drawings): A public toilet room is required for the newly framed and designed toilet room. Please revise all affected sheets. (2018 IPC section 403.3, Table 403.1, 2018 IEBC section 801.3)

4) Sheet MP2.0 (Plumbing and Mechanical Plans): Show water fountains or specify alternative source of drinking water. (2018 IPC section 410.1)

5) Sheet MP2.0 (Plumbing and Mechanical Plans): Show all plumbing fixtures in the DWV isometric diagram and detail the pipe sizes of all drain or vent segments and common vents. (2018 IPC section 106.3.1)

6) Sheet MP2.0 (Plumbing and Mechanical Plans): Missing a toilet room exhaust fan. Specify the CFM and vented to the exterior. (2018 IMC section 501.3, Table 403.3.1.1)



Mechanical(M) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 10/12/2023 1:22:33 PM
See the building review comments.



Electrical(E) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 10/12/2023 1:22:18 PM
See the building review comments



Plumbing(P) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 10/12/2023 1:23:04 PM
See the building review comments.
10/27/2023 Fire New Construction REQUIRES RESUBMIT Address SafeBuilt comments.
Questions: patricia.shelton@tucsonaz.gov / 520.837.7082
10/10/2023 PDSD Application Completeness Express REVIEW COMPLETED