Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1023-02344
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/30/2023 | Site Engineering | APPROVED | |||
10/24/2023 | Site Zoning | APPROVED | |||
10/19/2023 | Water - PDSD | APPROVED | |||
10/30/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
10/25/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 10/10/2023 3:52:42 PM See the building review comments. Building(B) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 10/10/2023 3:52:11 PM 1) General: Provide the design details, occupancy use, occupancy load, construction type, area, floor plans, elevations, structural design, foundations/footings, MEP plans, etc. for each structure. Drawings and construction details for many structures (covered bleachers, basketball court cover, each ramada, membrane structures, etc.) were not submitted. Include the exterior areas under roof cover (solid or membrane) in the building area and occupancy calculations. (2018 IBC section 107.1) 2) General: Show the accessible routes and areas for the structures and play areas. (2009 ICC A117.1 Sections 1101.2, 1108, 1108.4.1.3) 3) Sheets PVD05 through PVD11: The dugout drawings are labeled as Paving Details. (2018 IBC section 107.1) 4) Sheets PVD06 and SPN01: Incorrect codes shown. The structures are to be designed based on the 2018 ICC codes, 2017 NEC. 5) Sheet AP01: Show the accessible turning radius and the fixture clear floor spaces (with dimensions) in the toilet rooms and lavatories. (2009 ICC A117.1 sections 304.3, 305.3, 603.2.1, 606.2) Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Denied Reason: Date Completed : 10/19/2023 3:11:20 PM As per Plan Sheet MCP01 Note: RESTROOMS INCLUDE PERMANENT OPENINGS FOR NATURAL VENTILATION. SEE ARCH. SHEETS FOR DETAILS - Identify all locations of permanent openings on Mechanical Plans. Identify Plan sheets on Arch. sheets which show permanent openings. Provide diagram with dimensions of the permanent openings, 2018 IMC Chapter 402.2 Natural Ventilation and 2018 IBC Section [A]107.2.1Information on construction documents. and Plan Sheet STP10 shows as per RESTROOM FRAMING KEYNOTES: #2 MECHANICAL PENETRATIONS IN MASONRY WALL. COORDINATE SIZE AND LOCATION WITH MECHANICAL PLANS. - #2 is denoted on Restroom Foundation Plan. Please clarify where the openings are. 2018 IBC Section [A]107.2.1Information on construction documents. As per the City of Tucson Website - Building Codes As Adopted by City of Tucson The City of Tucson has adopted the 2018 International Building Codes with local amendments. All permits applications submitted after January 2, 2019 will use the 2018 Codes. Sheet SPN01 Under the Code Compliance Schedule State 2012 IBC. Confirm adopted codes - 2018 IBC Section [A]107.2.1Information on construction documents. Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 10/23/2023 11:05:36 AM Electrical Review of Murrieta Park By: Ron Ross PE ELP12: Could not locate Keynote 2. ELP13: Could not locate Keynotes 2 & 3 Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 10/24/2023 10:42:14 PM First plumbing review: 1).Need to address building plan review comments 1 & 4 -IPC 403.1 2). Lavatories on plan pages PLP03, PLP04, PLP08 needs hot water -IPC 607.1 and then will need ASSE 1070 mixing valves -IPC 419.5 3). Facility needs high low drinking fountain(s) -IPC 403.1 update all affected pages |
||
10/25/2023 | Fire New Construction | REVIEW COMPLETED | |||
10/05/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |