Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-1023-02314
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/02/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/29/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-1023-02314 6211 E. Speedway Bl. – C-2 Animal Service (3rd Review) TRANSMITTAL: December 29, 2023 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in C-2 zone (UDC 4.7.21), Animal Service – Boarding is a permitted use in the zone (UDC Table 4.8-4) as a [2] Zoning Examiner Special Exception Procedure, Section 3.4.3, subject to Use Specific Standards 4.9.4.D.9 - .15. 1. As Development Package (DP) TD-DEV-1123-00443 has not yet completed the first review Zoning cannot compare the plans for compliance with each other. Zoning will review the building plans on the next submittal. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 01/02/2024 | External Reviewers - SAFEBuilt | REVIEW COMPLETED | Structural(S) Reviewer (from previous submittal TUC9414001.100323) Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 10/13/2023 2:11:23 PM Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 10/13/2023 3:29:10 PM Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Approved Reason: Date Completed : 11/17/2023 7:00:12 PM 1. As per 2018 IMC Table 403.3.1.1 - Pet shops (animal areas)b. Note b states "Mechanical exhaust required and the recirculation of air from such places is prohibited. Recirculation of air that is contained completely within such spaces shall not be prohibited. (See section 403.2.1, item 3). (RESOLVED) 2. RTUs #6 supplies and returns air to animal areas and reception area. RTU #7 supplies and returns air to animal areas and Kitchen and Break Room This is prohibited by 2018 IMC Table 403.3.1.1 - Pet shops (animal areas)b (RESOLVED) Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved Reason: Date Completed : 11/17/2023 2:40:36 PM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved Reason: Date Completed : 12/30/2023 3:06:06 PM Third Plumbing Review: OK Subject to field inspections Resolved-1). This occupancy type & load requires a high/low drinking fountain. update all affected pages -IPC 403.1 2). Resolved-Floor sinks in grooming rooms on plan pages P1.1 & P2.0 needs to connect to a hair interceptor -IPC 1003.1 ** Grooming room wash tubs or floor sink still need hair interceptor(S)** 3). Resolved-What is the use of the various floor sinks not located near any indirect discharging fixtures or appliances on plan pages P1.1 & P2.0 ? -IPC 106.3.1, 801.1 4). Resolved-Show the Gas water heater intake & exhaust routing within the plumbing or mechanical pages. -IFGC 304, 503.1 |
||
| 12/22/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |