Review Details: COMMERCIAL REVIEW - FULL REVISION v.1
Permit Number - TC-COM-1023-02314
Review Name: COMMERCIAL REVIEW - FULL REVISION v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/10/2025 | Commercial Building Standard | APPROVED | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Approved Reason: Date Completed : 3/4/2025 8:15:27 PM Revisions outlined in "Narrative_v1.pdf" uploaded on March 4, 2025 do not impact Structural Review. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 3/10/2025 11:19:02 AM |
||
| 03/10/2025 | Commercial Electrical Standard | APPROVED | Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 3/4/2025 8:25:37 AM No electrical modifications shown or called out in narrative. |
||
| 03/10/2025 | Commercial Mechanical Standard | APPROVED | Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Approved Reason: Date Completed : 3/7/2025 11:23:08 AM |
||
| 03/21/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/10/2025 | Commercial Plumbing Standard | REQUIRES RESUBMIT | Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 3/8/2025 7:37:21 AM REVISE PLAN PLUMBING REVIEW: 1). GENERAL: Revised plumbing plans missing from revision set. Provide Revised plumbing plans , the original approved plumbing plan pages existing womens restroom layout doesn't match newly provided plan page A4.0. Update plans so pages correlate. -2018 IPC 106.3.1 2). Plan pages A0.7 & A4.0: High-Low drinking fountain can't be eliminated. Total Occupancy load of 27 requires a high-low drinking fountain. -2018 IPC 403.1 ** Update all affected pages** |
||
| 03/21/2025 | Site Zoning Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-1023-02314 6211 E SPEEDWAY BL - C-2 PAW COMMONS (1st Review) TRANSMITTAL DATE: March 21, 2025 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-2 zone (UDC 4.7.21). Commercial Animal Service General is an approved use in the zone (UDC Table 4.8-4), subject to Use Specific Standards 4.9.4.D.9-15 & a Zoning Examiner Special Exception Procedure, Section 3.4.3. 1. Sheet SP-1 Site Plan does not match approved Development Package (DP) TD-DEV-1123-00443, i.e. the accessible parking located near the southeast corner of the building, the area located north of the dog yard and the site plan calls out a new 5’ high cmu wall, keynote 18 and the DP calls out existing fence to remain, keynote 6. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 03/05/2025 | Fire New Construction Standard | REVIEW COMPLETED | Any Fire Sprinkler alteration will required a separate permit. Fire Extinguishers installation shall comply with the 2024 IFC section 906. |
||
| 03/03/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |