Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0926-01499
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/14/2026 | Site Engineering Standard | APPROVED | |||
| 09/30/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/21/2026 | Commercial Building Standard | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov 1. Please revise the site plans to provide a unique label for each carport structure to ensure each permit is clearly associated with the appropriate carport. Use the same alphanumeric identifiers established during permit creation (e.g., A1, A2, A3, A4, A5, B1, B2, etc.).2024 IBC 107.2.1 2. Please update and resubmit the structural calculations to reflect the currently adopted 2024 IBC and ASCE/SEI 7-22. The submitted calculations reference the 2018 IBC and ASCE/SEI 7-16. Update the design criteria, load assumptions, and calculations as applicable, and provide the revised calculations with the next resubmittal. 2024 IBC 1603.1, 1604.1; ASCE/SEI 7-22. Please contact me if you have any questions about the above comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 09/30/2026 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Jeffrey W. Cassidy, Planner I Planning & Development Services Department – Current Zoning Review Section, Commercial PROJECT: TC-COM-0926-01499 – Commercial – CARPORT D10 2945 N BEAR CANYON RD TUCSON, AZ 85749 (R-3 Zoning) Commercial Building Plan Review – 1st Review TRANSMITTAL DATE: September 30, 2026 1. COMMENT: Please revise the site plans to provide a unique label for each carport structure to ensure each permit is clearly associated with the appropriate carport. Use the same alphanumeric identifiers established during permit creation (e.g., A1, A2, A3, A4, A5, B1, B2, etc.). Clearly highlight where Carport D10 / TC-COM-0926-01499 is proposed to go on the site plan sheet. 2. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: 3. COMMENT: Corrected building permit. 4. COMMENT: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home . Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code . |
||
| 09/10/2026 | PDSD Application Completeness Express | REVIEW COMPLETED | Main permit is TC-COM-0926-01448 and the Bluebeam session for it is 895-359-340 . |