Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0926-01481
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/06/2026 | Commercial Building Standard | APPROVED | |||
| 10/07/2026 | Commercial Plumbing Standard | APPROVED | |||
| 10/07/2026 | Site Zoning Standard | APPROVED | |||
| 10/07/2026 | Water - PDSD Standard | APPROVED | |||
| 09/25/2026 | Outdoor Lighting Standard | NOT REQUIRED | No modifications to the outdoor lighting. | ||
| 09/24/2026 | Site Engineering Standard | NOT REQUIRED | |||
| 10/08/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/29/2026 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0926-01481 (6255 E GRANT RD TUCSON, AZ 85712) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Reference Sheet E-1, Plan Notes #6. The replacement of all outdoor equipment, including HVAC units, requires GFCI protected per NEC 210.8(F). Verify if GFCI protection is required for this replacement AC unit. 2. Show or note GFCI protection for all new or modified receptacles per NEC 210.8(B)(2),(3) &(4) and any new equipment outlets listed in NEC 210.8(D). |
||
| 10/07/2026 | Commercial Mechanical Standard | REQUIRES RESUBMIT | Provide heating and cooling load calculations to justify the heating/cooling capacities of the specified HVAC units. Reference: Section C403.1.1 and C502.2.3, IECC 2024 and Section 312.1, IMC 2024. If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov. |
||
| 10/08/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 09/17/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |