Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0926-01471
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/17/2026 | Commercial Electrical | APPROVED | |||
| 09/23/2026 | Site Zoning | APPROVED | |||
| 09/24/2026 | Water - PDSD | APPROVED | |||
| 09/24/2026 | Commercial Mechanical | NOT REQUIRED | |||
| 09/16/2026 | Site Engineering | NOT REQUIRED | |||
| 09/25/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/25/2026 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov 1. Please provide structural documentation verifying that the existing/proposed roof trusses are designed and capable of supporting the 100-pound suspended shelving load, including the shelving dead load and all applicable imposed loads. Provide revised truss calculations/design documentation prepared or approved by the registered design professional where required. 2024 IBC Sections 1604.2, 1604.3, 1607.1 and 2303.4.1.1. Section 2303.4.1.1 requires truss design drawings to identify applicable design loads, including additional loads and their locations. Please contact me if you have any questions about the above comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 09/24/2026 | Commercial Plumbing | REQUIRES RESUBMIT | 1. Identify where a 3” cleanout is located for the 3” grease waste. Reference: Section 708.1.1, IPC 2024. 2. The Blendtec Rapid Rinse Station connects directly to potable water and handles food waste, raising the possibility of a cross-connection. Specify a backflow protection device that is listed for the intended application. Reference: Section 608.1, IPC 2024. 3. If the 3-compartment sink is used only for washing, rinsing, and sanitizing utensils used for food service, the sink shall drain indirectly to the grease interceptor with an air gap or an air break. If, however, the 3-compartment sink is also used for the preparation of food items, separate indirect waste pipes shall be provided for each compartment to protect against cross-contamination or fouling and each indirect drain shall terminate with an air gap. Reference: Sections 801.2, 802.1.1, and 802.1.7, IPC 2024. 4. All of the vents shall rise vertically to at least 6” above the flood rims of the fixtures they protect prior to running horizontally (occurs 2 places). Reference: Section 905.4, IPC 2024. If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov |
||
| 09/22/2026 | Fire New Construction | REVIEW COMPLETED | |||
| 09/11/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |