Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-0925-01769
Parcel: 111051560

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0925-01769
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/09/2025 Commercial Building APPROVED
10/09/2025 Commercial Mechanical APPROVED
10/08/2025 Fire New Construction NOT REQUIRED
10/21/2025 Site Zoning NOT REQUIRED
10/21/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/02/2025 Commercial Electrical REQUIRES RESUBMIT Commercial Electrical Review TC-COM-0925-01769 (3052 N SPARKMAN BL TUCSON, AZ 85716)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC).

Electrical Review:
1. Provide an electrical plan showing any/all electrical work.
Plans shall include (as necessary for scope of work), but may not be limited to items below:
2. Provide electrical load calculations, for the Main Service Panel showing it can support the additional load, Per NEC 220.40.
3. Show all wiring methods in detail for all new or modified branch circuit conductors and feeders. Conductor type and conduit size/type. Note wet use requirements. NEC arts;300 and 408.4.
4. Provide a panel schedules, showing the circuits that are being modified, added or removed or existing. NEC arts;300 and 408.4. Include panel bus rating and A.I.C. rating. IBC 107.1.
5. Designate the circuit number on the electrical plans, that corresponds to the panel schedule, at the location of each existing, new or modified light fixture, receptacle, and equipment disconnect switch, NEC arts;300 and 408.4. IBC 107.1.
Additional comments may be forthcoming with the receipt of a complete plan set.
6. On the Site Plan, locate/identify/label the building this unit is located, show the shape of the unit within the building footprint.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
09/29/2025 PDSD Application Completeness Express REVIEW COMPLETED