Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0925-01762
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/10/2025 | Commercial Electrical Standard | APPROVED | |||
| 10/16/2025 | Commercial Mechanical Standard | APPROVED | |||
| 10/16/2025 | Commercial Plumbing Standard | APPROVED | |||
| 10/16/2025 | Water - PDSD Standard | APPROVED | |||
| 10/24/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/20/2025 | Commercial Building Standard | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. 1. Please provide the following information for the Use and Occupancy Classification. A. Please amend plans for buildings with more than one occupancy classification identify the mixed occupancy methodology as either accessory, nonseparated, separated, or a stated combination of types. IBC 508.1 2. Please provide the following information for the methodology(s) used in determining the allowable area for the mixed occupancies. A. Nonseparated occupancies allowable building area, building height, and number of stories is the most restrictive of any of the nonseparated occupancies. IBC 508.3.2 B. The separated occupancy’s equation of summed ratios for each story is shown with the values used and each story does not exceed 1. IBC 508.4.2 C. The separated occupancy’s individual story’s summed ratios are shown added together and together do not exceed 3. IBC 506.2.4 3. Please provide the following information for fire-resistance and smoke separation protective systems(s). A. The fire-resistance rating of all walls and elements is shown on each floor’s plan view. IBC 602.1 B. An indication of where to find the construction information for the fire-rated assemblies, openings and penetrations. IBC 703.3 For provide construction details with basis of approval by one of the following: i. Listing number approved by third-party testing agency (i.e., UL, GA) ii. Item number for prescriptive fire-resistive assembly under IBC Table 721.1(2) iii. Prescriptive assembly constructed under IBC 722.6. Note. Provide manufacturer specification sheets within the plans detailing the assembly to match listing requirements. Cross-reference this detail on plans. (Treat as a Typical Note) for all rated assemblies and firestop/penetration methodologies. IBC 107.2.1 C. Openings in separation walls and floors have a reference where to find information. IBC 716.1, 717.1 Note. Provide manufacturer specification sheets within the plans detailing the assembly to match listing requirements. Cross-reference this detail on plans. (Treat as a Typical Note) for all rated assemblies and firestop/penetration methodologies. IBC 107.2.1 D. Penetrations in walls and floors are identified with a reference where to find information. IBC 714.1 Note. Provide manufacturer specification sheets within the plans detailing the assembly to match listing requirements. Cross-reference this detail on plans. (Treat as a Typical Note) 4. for all rated assemblies and firestop/penetration methodologies. IBC 107.2.1 Please provide the following information for means of egress system. A. The size of each egress door and stairway is shown and is compared to allowable. IBC 1005.3 Please provide a plan view drawing of a typical side hinged door, within a dimension depicting the clear opening. If other than 34” clear opening is shown, please update the capacity of each door. B. If necessary, please change the number of occupants being served by each egress door and stairway is shown if clear opening of door is reduced. IBC 107.2.3 5. Please amend structural calculations to update the project name, as to not indicate a residence, but reference this project. IBC 107.2.1 6. Please provide glass fence and connection design, calculations and construction drawings and details, sealed by an Arizona licensed registrant with next submittal. IBC 107.2.1 Referenced on sheet S1.3 details 22,23,24. 7. Please amend the sheet index list so it includes all the drawing sheets in this permit’s scope. IBC 107.2.1 For example sheets A2.0, is not listed in the index, but is included in the plan set; and sheets E0.0, and E1.3 are listed in the sheet index, and not included in the plan set. Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 10/09/2025 | Outdoor Lighting Standard | REQUIRES RESUBMIT | Outdoor Lighting Review TC-COM-0925-01762 (1010 N FINANCE CENTER DR TUCSON, AZ 85710) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). Outdoor Lighting Review: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf 1. Provide an outdoor site lighting plan that meets the requirements of OLC 104.2. Show/locate the different light sources on your site plan. Number the light fixtures on your lighting fixture table and use the same number on your site plan. 2. List the Lighting Area per OLC (Typically E3) chapter 3 and used in Table 401.1. Specify the compliance option from Table 401.1 that is being used. Total outdoor light output shall not exceed the lumen limits listed in Table 401.1. 3. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 104.2.1, 401.2. Include all exterior fixtures on the property in the calculations. List shielded and unshielded lights in the calculation. 4. Show unshielded fixtures with a maximum of 3,000 lumens, OLC 401.4. 5. Show lamps with a maximum of 3500K color temperature, OLC 402.1. 6. Indicate whether or not a special inspection is required per sec. 104.2.2, and 106.2. https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate_odl.pdf 7. Specify any exceptions used. 8. Provide Curfew lighting controls If applicable Per section 403. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 10/14/2025 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TC-COM-0925-01762 Location: 1010 N FINANCE CENTER DR Review Date: 10/14/2025 Site Engineering Comments: 1. Site Engineering will be unable to review and approve permit TC-COM-0925-01762 until the associated development package TD-DEV-1025-00253 is reviewed and approved by all reviewers. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 10/24/2025 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-COM-0925-01762 - TD-DEV-1025-00253 1010 N. Finance Center Dr. Tucson, AZ 85710 Modification of an existing building to accommodate multiple tenants (1st Review) TRANSMITTAL DATE: 10/24/2025 The site is located in PAD-3 (Gateway Centre PAD). Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: Zoning has reviewed the plans for compliance with Development Package (DP) TD-DEV-1025-00253 and although the plans appear to match, until the DP is approved by all review agencies Zoning cannot approve this permit. 2. Comment: Additional comments may be forthcoming on the next review based on the plans submitted and responses to zoning review comments. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 10/16/2025 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 09/26/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |