Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0924-01858
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/09/2024 Commercial Plumbing APPROVED
10/14/2024 Site Engineering APPROVED
10/03/2024 Site Zoning APPROVED
10/09/2024 Water - PDSD APPROVED
10/14/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
10/09/2024 Commercial Building REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0924-01858
ADDRESS/PARCEL: (160 S AVENIDA DEL CONVENTO Unit:UNIT 176 TUCSON, AZ 85745)
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter.
COMMENTS:
1. Please locate and label ALL the Restrooms, the Mop Sink and Drinking Fountain in the Site Plan.
2. Please resubmit.
10/08/2024 Commercial Electrical REQUIRES RESUBMIT Please provide compliance with the 2018 IECC for the lighting.
Ref; 2018 IBC section 107.2.1, 2017 NEC, 2018 IECC
10/09/2024 Commercial Mechanical REQUIRES RESUBMIT 1. The minimum openable area for natural ventilation is based on the total floor area being ventilated. With no separation between the three areas and all of the ventilation air being supplied via the entry door, the required exhaust must also be based on the total area. Provide additional exhaust for the suite. Reference: Sections 402.6 and 403.2.1.(3), IMC 2018.
2. Nail salons require a source-capture exhaust system for each manicure station. The exhaust inlets shall be located a maximum of 12” horizontally and 12” vertically from the point of chemical application. Provide a detail showing how this is to be accomplished. Reference: Table 403.3.1.1, footnote h and Section 502.20, IMC 2018.
09/30/2024 Fire New Construction REVIEW COMPLETED
09/27/2024 PDSD Application Completeness REVIEW COMPLETED