Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0924-01847
Parcel: 133160450

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW REVISION v.2

Permit Number - TC-COM-0924-01847
Review Name: COMMERCIAL PDSD SIMPLE REVIEW REVISION v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/13/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/13/2025 Commercial Electrical Fast REQUIRES RESUBMIT Commercial Electrical Review TC-COM-0924-01847 (6408 E TANQUE VERDE RD TUCSON, AZ 85715)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC).

1. You cannot use previously Sealed documents, even with the Seal removed. Please submit a new and original diagram showing the installation of the TEP required 5th jaw.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
02/13/2025 PDSD Application Completeness Express REVIEW COMPLETED