Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.2
Permit Number - TC-COM-0924-01831
Review Name: COMMERCIAL REVIEW - LIMITED v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/24/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
10/24/2024 | Commercial Building | REQUIRES RESUBMIT | October 23, 2024 2nd Review Swaim Associates Attn: Ed Marley 7350 E. Speedway Blvd., Suite 210 Tucson, Arizona 85710 Re: MISTER CARWASH - SPEEDWAY REMODEL City of Tucson Permit Number: TC-COM-0924-01831 Stantec Project Number: 185215066 Stantec File Number: TUC-24-130 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, and plumbing designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 3,388 19 No No Separate Permits: None. Deferred Submittals: None. Special Inspections: Earthwork, concrete, epoxy and expansion anchors, structural steel, high-strength bolts, field welding, masonry and EIFS. ARCHITECTURAL COMMENTS General 1. Addressed. Sheet g1.0 1. Previous Comment: Please also include on this sheet that special inspection is required for earthwork, structural steel, high-strength bolts, field welding, and masonry as outlined on Sheet S1.1. Also, provide City of Tucson special inspection certificate(s) with Parts A and B completed for all special inspections. Make sure that the owner or their legal representative signs the form. Still Required: The special inspection certificate provided is missing the special inspection for EIFS and the special inspector performing the inspection. Please provide an updated special inspection certificate. Sheet g2.0 1. Addressed. 2. Addressed. STRUCTURAL COMMENTS Structural Calculations 1. Addressed. Sheet S2.0 1. Addressed. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
10/18/2024 | PDSD Application Completeness | REVIEW COMPLETED |