Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0924-01750
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/15/2024 | Site Engineering | APPROVED | |||
10/10/2024 | Site Zoning | APPROVED | |||
10/14/2024 | Water - PDSD | APPROVED | |||
10/15/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
10/02/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Approved Reason: Date Completed : 9/29/2024 10:21:47 PM Building(B) Reviewer Kimiyoshi Shimabukuro kshimabukuro@safebuilt.com Denied Reason: Date Completed : 9/21/2024 1:29:19 PM 1. FS-K design documents missing registered design professional stamp/seal/date. 2. G101: 2021 codes are reference so provide the applicable accessible codes for this design documents. City of Tucson has adopted 2018 IBC with local amendments. City of Tucson IBC Local Amendments • Amendments to the 2018 International Building Code • Amendments to the 2018 International Existing Building Code • Amendments to the 2018 International Energy Conservation Code • Amendments to the 2018 International Fuel Gas Code • Amendments to the 2018 International Mechanical Code • Amendments to the 2018 International Plumbing Code • Amendments to the 2018 International Residential Code • Amendments to the 2018 International Swimming Pool & Spa Code • Amendments to the 2017 National Electrical Code • Amendments to the 2018 International Fire Code • City of Tucson/Pima County Outdoor Lighting Code • Arizona Administrative Code Title 18 Chapter 5 for public and semi-public swimming pools • ICC A117.1 - 2009 Accessible and Usable Buildings and Facilities (by reference) Adopting Local Amendments to the Building Code is authorized by Ordinance #11590. 3. G102: In plumbing fixture calculation, water closet for woman states 5.6 required but provided 5 not 6 rounded up to the next whole number. 4. G102: 2018 IBC section 1006.2.1.1 requires three exists or exit access doorways shall be provided from any space with an occupancy of 501 to 1,000. This facility shows 722 occupants without 3 exists or exit access doorways. 5. G102: Egress doors such as double door in storage do not swing in the direction of egress travel (2018 IBC section 1010.1.2.1). 6. G102: Related issue of storage door – 2018 IBC section 1016.2 part 5 involving egress shall not pass through storage that is egress through intervening space. Similar issue traveling through the kitchen. 7. G102: Fire separation protection of demising wall is undefined between this A-3 occupancy and adjacent tenant (2018 IBC table 508.4). 8. G102: Does not show location(s) of Automated External Defibrillator. Explain as registered design professional. 9. G103: Fire extinguisher cabinet detail missing. 10. G202: Site plan including accessible route of travel such as accessible parking space to public entry is missing. 11. Roof plan missing to provide roofing scope of work. M102: Roof top access method not defined to inspect/maintain appliances (2018 IMC section 306). 12. S001: Missing statements of special inspections per 2018 IBC chapter 17. 13. A503: Provide the drawings of play structure – only typical elevation provided (2018 IBC section 107). A111 note 1 shows “play equipment by others.” Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Denied Reason: Date Completed : 9/30/2024 10:03:51 AM 1. General - Provide Heat Load Calculations. Heat Load Calculations must match Design on plans. - 2018 IECC Section C403.1.1 Calculation of heating and cooling loads. 2. General - Provide Listed Manufacturer Grease Hood Plans - 2018 IMC Sections 506, 507, and 508 - NFPA 96 3. General - Provide Fire Suppression Plans. Show all cooking equipment under hood. Show nozzle placement over equipment. - 2018 IMC Section 509 - NFPA 96 4. Plan Sheet M602 - Plan Sheet M602 states on the Minimum Required Ventilation Rates Schedule Header IN ACCORDANCE WITH THE 2021 INTERNATIONAL MECHANICAL CODE. The adopted codes for Tucson, Arizona are 2018 IMC, 2018 IECC. - Specify on the drawings the outdoor air required by the 2021 IMC Section 403.3.1.1 Substantiate compliance by providing calculations on the drawings which indicates the floor area (sq. ft), maximum occupant load, minimum required ventilation rate (cfm) for each occupancy, and total ventilation rate provided to the occupied space. - 2018 IMC Section 403 Table 403.3.1.1 5. Plan Sheet M601 - Provide on the Existing Rooftop Unit Design Schedule the CFM quantities for each specific unit design. RTU CFM values do not match the Supply Fan Max Air Flow (CFM) amounts for each specific SAD (supply air drops) amounts (CFM) RTU #3, RTU #6, RTU #11, RTU #12, - 2018 IBC – Section [A]107.2.1Information on construction documents. - 2018 IECC Section C103.2Information on construction documents. Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 9/20/2024 6:53:06 AM 1. E601 ELECTRICAL SCHEDULES panel DP should show an estimated load for existing panels PA and PD or call out the new loads as ‘Newly added Loads”. Should confirm that the added new loads plus the existing loads will not overload panel DP, but engineering judgement is assumed. 2. E602 ELECTRICAL SCHEDULES comment only, Panel K could be upsized to 800 amps per NEC table 450.3. 3. K101 KITCHEN ELECTRICAL LAYOUT electrical kitchen items 47-54, and 60 not identified/shown. Commentsuggestion only: Could use electrical remarks to reference K104 # elevation to call out location. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 10/1/2024 10:55:19 PM FIRST PLUMBING REVIEW: 1). General: Need to address Building plan review comments 1, 2, 3 - 2018 IPC 106.3.1, 403.1, 2). Plan page P501: Missing Grease interceptor sizing calculations. Add grease interceptor sizing calculations. -Tucson Plumbing code amendments chapter 10 3). General Plumbing Plans: Missing gas piping plans illustrations & information to correlate with the gas appliances stated on plan page FSK-100- 2018 IFGC 106.3.1, 402.3, 403 4). Plan Page P601: Missing beverage equipment backflows. Add a backflow schedule to correlate with the beverage equipment listed on plan page FSK-100 - 2018 IPC 608.17.1 |
||
10/11/2024 | Fire New Construction | REQUIRES RESUBMIT | Resolve SAFEBuilt comments. Questions: patricia.shelton@tucsonaz.gov |
||
09/16/2024 | PDSD Application Completeness | REVIEW COMPLETED |