Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0924-01750
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/25/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
11/18/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer (from previous submittal TUC9601001.091624) Madeline Nelson mnelson@safebuilt.com Approved Reason: Date Completed : 9/29/2024 10:21:47 PM Building(B) Reviewer Kimiyoshi Shimabukuro kshimabukuro@safebuilt.com Approved with Comments Reason: Date Completed : 11/14/2024 5:31:57 AM Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel, or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The registered design professional is responsible for following ALL applicable Federal, State, and local Municipal Codes and Ordinances Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Denied Reason: Date Completed : 11/14/2024 6:26:42 PM 1. General - Provide Heat Load Calculations. Heat Load Calculations must match Design on plans. - 2018 IECC Section C403.1.1 Calculation of heating and cooling loads. 2. (UNRESOLVED) - General - Provide Listed Manufacturer Grease Hood Plans - 2018 IMC Sections 506, 507, and 508 - NFPA 96 i. Provide Listed Manufacturer Grease Hood Plans - 2018 IMC Sections 506, 507, and 508 - NFPA 96 3. (RESOLVED) - General - Provide Fire Suppression Plans. Show all cooking equipment under hood. Show nozzle placement over equipment. - 2018 IMC Section 509 - NFPA 96 4. (RESOLVED) - Plan Sheet M602 - Plan Sheet M602 states on the Minimum Required Ventilation Rates Schedule Header IN ACCORDANCE WITH THE 2021 INTERNATIONAL MECHANICAL CODE. The adopted codes for Tucson, Arizona are 2018 IMC, 2018 IECC. - Specify on the drawings the outdoor air required by the 2021 IMC Section 403.3.1.1 Substantiate compliance by providing calculations on the drawings which indicates the floor area (sq. ft), maximum occupant load, minimum required ventilation rate (cfm) for each occupancy, and total ventilation rate provided to the occupied space. - 2018 IMC Section 403 Table 403.3.1.1 5. (UNRESOLVED) - Plan Sheet M601 - Provide on the Existing Rooftop Unit Design Schedule the CFM quantities for each specific unit design. RTU CFM values do not match the Supply Fan Max Air Flow (CFM) amounts for each specific SAD (supply air drops) amounts (CFM) RTU #3, RTU #6, RTU #11, RTU #12, - 2018 IBC – Section [A]107.2.1Information on construction documents. - 2018 IECC Section C103.2Information on construction documents. i. RTU #3 Supply Air Drop CFM total quantity does not match the Existing RTU Schedule CFM total for RTU #3 - 2018 IBC – Section [A]107.2.1Information on construction documents. - 2018 IECC Section C103.2Information on construction documents. ii. RTU #6 Supply Air Drop CFM total quantity does not match the Existing RTU Schedule CFM total for RTU #6 - 2018 IBC – Section [A]107.2.1Information on construction documents. - 2018 IECC Section C103.2Information on construction documents. iii. RTU #11 Supply Air Drop CFM total quantity does not match the Existing RTU Schedule CFM total for RTU #11 - 2018 IBC – Section [A]107.2.1Information on construction documents. - 2018 IECC Section C103.2Information on construction documents. iv. RTU #12 Supply Air Drop CFM total quantity does not match the Existing RTU Schedule CFM total for RTU #12 - 2018 IBC – Section [A]107.2.1Information on construction documents. - 2018 IECC Section C103.2Information on construction documents. Electrical(E) Reviewer (from previous submittal TUC9601001.091624) Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 9/20/2024 6:53:06 AM 1. E601 ELECTRICAL SCHEDULES panel DP should show an estimated load for existing panels PA and PD or call out the new loads as ‘Newly added Loads”. Should confirm that the added new loads plus the existing loads will not overload panel DP, but engineering judgement is assumed. 2. E602 ELECTRICAL SCHEDULES comment only, Panel K could be upsized to 800 amps per NEC table 450.3. 3. K101 KITCHEN ELECTRICAL LAYOUT electrical kitchen items 47-54, and 60 not identified/shown. Commentsuggestion only: Could use electrical remarks to reference K104 # elevation to call out location. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 11/17/2024 10:15:47 AM SECOND PLUMBING REVIEW: RESOLVED-1). General: Need to address Building plan review comments 1, 2, 3 - 2018 IPC 106.3.1, 403.1, RESOLVED-2). Plan page P501: Missing Grease interceptor sizing calculations. Add grease interceptor sizing calculations. - Tucson Plumbing code amendments chapter 10 UNRESOLVED-3). PLAN PAGE FSK-100: Missing gas piping plans illustrations & information to correlate with the gas appliances stated on plan page. **OR UPDATE OLAN PAGE FSK-1OO TO CORRELATE PLAN PAGE E602 & RESPONSE COMMENTS**( STILL SHOWS GAS FOR ITEMS-#52,53)- 2018 IFGC 106.3.1, 402.3, 403 RESOLVED-4). Plan Page P601: Missing beverage equipment backflows. Add a backflow schedule to correlate with the beverage equipment listed on plan page FSK-100 - 2018 IPC 608.17.1 |
||
11/25/2024 | Fire New Construction | REVIEW COMPLETED | |||
11/12/2024 | PDSD Application Completeness | REVIEW COMPLETED |