Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0924-01728
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/03/2024 | Water - PDSD | APPROVED | |||
10/07/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
09/23/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Approved Reason: Date Completed : 9/20/2024 7:28:38 PM Building(B) Reviewer Kimiyoshi Shimabukuro kshimabukuro@safebuilt.com Approved Reason: Date Completed : 9/7/2024 11:54:58 PM Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Denied Reason: Date Completed : 9/20/2024 4:07:27 PM 1. General - Provide Heat Load calculations. Include total Cooling load. Include all cooling. Separate by zone. Separate by unit types - 2018 IECC Section C403.1.1 Calculation of heating and cooling loads. 2. General - Provide Exhaust/Mechanical Ventilation/Makeup Air to Laundry and Maintenance areas. - 2018 IMC 403.1 Ventilation system. - 2018 IMC 504.6 Makeup air. - 502.1 General. 3. Plan Sheet M2.1 - Because of the higher than normal temperatures in the summer and the extremely cold temperatures in the winter, Natural ventilation is not allowed in Tucson, Arizona. Operable openings will not be opened for ventilation by the occupants. - Authority Having Jurisdiction - 2018 IMC Section 403 Table 403.3.1.1 - ASHRAE 4. Plan Sheet M2.1 - Include in the COMcheck Mechanical Compliance Certificate all HVAC equipment. (mini-splits and PTAC units) - 2018 IECC Section C403.3.2 HVAC equipment performance requirements. Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved Reason: Date Completed : 9/12/2024 2:40:16 PM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 9/21/2024 4:03:12 PM First Plumbing Review: 1). Plan page P1.3: Triple Washers missing LINT interceptor(s). Add lint interceptor due to multiple washers -2018 IPC 1003.6 2)-Plan Page A5.0: Missing Gutter & downspout sizing calculations: Add gutter & downspout sizing calculations. -2018 IPC 1106.3, 1106.6 3). Plan Plan page M1.1: Missing makeup/combustion air for gas dryers. Provide gas combustion Air illustrations & info for laundry room. -2018 IFGC 304 4). Plan Pages P1.3 & C5.0: These plan pages don't correlate as far as the Potable & Fire water mains bldg entrance locations. Update these plan pages to correlate. -2018 IPC 106.3.1 |
||
10/07/2024 | Site Engineering | REQUIRES RESUBMIT | The development package TD-DEV-0924-00246 must be approved before this building permit can be approved. Mike Ortiz michael.ortiz@tucsonaz.gov |
||
10/02/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-COM-0924-01728 - TD-DEV-0924-00246 835 W. Prince Rd., Tucson, AZ 85705 Multifamily Building with Clinic (1st Review) TRANSMITTAL DATE: October 2, 2024 Please resubmit revised drawings detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-2 zone (UDC 4.7.21). Multifamily development is a permitted use in this zone (Table 4.8-4). Medical service-outpatient, excluding blood donor centers, is a permitted use in this zone subject to use-specific standards 4.9.4.O.2 and 4.9.13.P. Zoning has reviewed the building plans for compliance with development package (DP) TD-DEV-0924-00246 and although it appears that the building plans match, until the DP is approved by all review agencies, Zoning cannot approve this building plan. Please ensure any changes made to the DP prior to approval are reflected on resubmitted building plans. If you have any questions about this transmittal, please contact Fernando Garcia at fernando.garcia2@tucsonaz.gov. |
||
10/03/2024 | Fire New Construction | REVIEW COMPLETED | |||
09/06/2024 | PDSD Application Completeness | REVIEW COMPLETED |