Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0923-02267
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/25/2023 | Water - PDSD | APPROVED | |||
| 10/18/2023 | Site Engineering | NOT REQUIRED | |||
| 10/25/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/29/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/29/2023 5:18:08 PM See the building review comments. Building(B) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/29/2023 5:16:37 PM 1) Sheet G001 (Cover Sheet): Provide the allowed vs actual building area, height, and number of stories. (2018 IBC Chapter 5) 2) Sheet G002 (Project Details): The occupant load has not been calculated correctly and some areas were not included in the calculations. The lobby/waiting area is to be calculated at 1 person per 5 sf for standing area, the partner and patio areas are to be calculated at 1 per 15 sf, the office is 1 per 150 sf (1 occupant), the entire kitchen area is 1 per 200 sf (labeled as Engine, BOH and the room not labeled but with the 3-compartment sink). Please revise all affected sheets. (2018 IBC section 1004 and Table 1004.5) 3) Sheet G002 (Project Details): The occupant load appears to exceed 25 and requires separate toilet rooms. Please revise the calculations and all affected sheets. (2018 IPC section 403.2) 4) Sheet G002 (Project Details): Show the outline of the roof on the floor plan and include the areas under the roof in the building area calculations. (2018 IBC section 107 and Chapter 2 Building Area definition) 5) Sheet E-1100 (Electrical Site Plan): Include the light pole drawings and details. (2018 IBC section 107) 6) Sheets E-1101 and E-1102 (Electrical Power Plan): Show all rooftop, exterior, receptacles within 6ft of a sink, and kitchen receptacles are GFCI protected. (2017 NEC sections 210.8(B)(2), (3), (4), and (5)) 7) Sheet E-1103 (Lighting Plan): Exit discharge lighting and the lighting for the patio dining space is not shown. (2018 IBC section 1008) 8) Sheet P100 (Plumbing Details): Provide the drainage fixture unit calculations for the correct DWV pipe sizing. (2018 IPC section 709.1) 9) Sheet P100 (Plumbing Details): Include the faucet details meeting the requirements of the amended 2018 IPC sections 412.11 and 419.6 for automatic faucets. 10) Sheet P100 (Plumbing Details): Provide the water heater and support drawings and details. (2018 IBC section 107) Mechanical(M) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/29/2023 5:17:31 PM See the building review comments. Electrical(E) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/29/2023 5:17:13 PM See the building review comments. Plumbing(P) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 9/29/2023 5:17:52 PM See the building review comments. |
||
| 10/02/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-COM-0923-02267 3100 East Speedway Boulevard – C-2 Starbucks tenant improvement (1st Review) TRANSMITTAL DATE: October 2, 2023 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. 1. The location and number of short-term bicycle parking spaces on TC-COM-0923-02267 does not match the location and number approved on associated development package TD-DEV-0123-00094. Either TD-DEV-0123-00074 will need to be revised to show these changes, or these changes shall be removed from the building permit plan set. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 10/02/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 09/26/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |