Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-0923-02267
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/13/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/13/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Keith Miller kmiller@safebuilt.com Approved Reason: Date Completed : 2/13/2024 5:17:24 PM The structural review is approved. Subject to the field inspector's approval. Building(B) Reviewer Keith Miller kmiller@safebuilt.com Approved Reason: Date Completed : 2/13/2024 5:16:15 PM The building review is approved. Subject to the field inspector's approval Mechanical(M) Reviewer Keith Miller kmiller@safebuilt.com Approved Reason: Date Completed : 2/13/2024 5:17:00 PM The mechanical review is approved. Subject to the field inspector's approval. Electrical(E) Reviewer Keith Miller kmiller@safebuilt.com Approved Reason: Date Completed : 2/13/2024 5:16:37 PM The electrical review is approved. Subject to the field inspector's approval. Plumbing(P) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 2/13/2024 5:15:21 PM 1) Resolved - Sheets P100 (Plumbing Details), I401, I402: Provide the drainage fixture unit calculations for the correct DWV pipe sizing. (2018 IPC section 709.1) Drainage fixture unit calculations do not match the provided and required plumbing fixtures. There are two water closets shown on the plans and the minimum required two lavatories are to be located in the toilet facilities. Include the accessibility details for all accessories and lavatories in the revised toilet facility design. 2) Resolved - Sheet P100 (Plumbing Details): Include the faucet details meeting the requirements of the amended 2018 IPC sections 412.11 and 419.6 for automatic faucets. Faucet details not provided. 3) Resolved - Sheet P100 (Plumbing Details): Provide the water heater and support drawings and details. (2018 IBC section 107) 4) Unresolved – Sheets P102, P302: The existing grease interceptor listed appears to be a hydromechanical type of grease interceptor (no additional details provided). The amended 2018 IPC section 1003.3 prohibits hydromechanical grease interceptors being used for more than 4 fixtures. Please provide a letter from the building official if the amended grease interceptor requirements are being waived. |
||
| 02/13/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |