Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0923-02153
Parcel: 10120033G

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0923-02153
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/04/2023 Water - PDSD APPROVED MASTER SET LOCATED AT: TC-COM-0923-02153 (4995 N CASA GRANDE HY TUCSON, AZ 85743) Bldg 1 & 3 (Outbuilding), Studio Session 394-308-094 WITH REVIEW NOTES TO BE COPIED ON TC-COM-0923-02259 (4985 N CASA GRANDE HY TUCSON, AZ 85743)
09/22/2023 Site Engineering NOT REQUIRED MASTER SET LOCATED AT: TC-COM-0923-02153 (4995 N CASA GRANDE HY TUCSON, AZ 85743) Bldg 1 & 3 (Outbuilding), Studio Session 394-308-094 WITH REVIEW NOTES TO BE COPIED ON TC-COM-0923-02259 (4985 N CASA GRANDE HY TUCSON, AZ 85743)
10/04/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT MASTER SET LOCATED AT: TC-COM-0923-02153 (4995 N CASA GRANDE HY TUCSON, AZ 85743) Bldg 1 & 3 (Outbuilding), Studio Session 394-308-094 WITH REVIEW NOTES TO BE COPIED ON TC-COM-0923-02259 (4985 N CASA GRANDE HY TUCSON, AZ 85743)
09/25/2023 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Structural(S) Reviewer
Daljit Benipal
dbenipal@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 9/18/2023 5:42:42 PM
NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances.



Building(B) Reviewer
Andrew Bevis
abevis@safebuilt.com
Approved
Reason:
Date Completed : 9/15/2023 11:10:43 AM



Mechanical(M) Reviewer
Jorge Valido
jvalido@safebuilt.com
Denied
Reason:
Date Completed : 9/21/2023 10:40:27 AM
Provide ductwork for exhaust fans (EF-2 & EF-3). Provide termination locations at exterior of building. 2018 IMC – Section [A]107.2.1 Information on construction documents.

Show ductwork on plans for all AHUs in Bldg. #2. Show existing and new/modified as per Mechanical plan Key Notes on Plan sheet H100b & H101b. Show Supply Air Drop CFM quantities. Show O/A quantity for all AHUs. 2018 IMC – Section A]107.2.1 Information on construction documents.

Provide ventilation schedule for Bldgs. 1 & 2 as per 2018 IMC TABLE 403.3.1.1 MINIMUM VENTILATION RATES
Provide tie down requirements for condensers 2018 IMC Chapter 3

Provide FCU installation specification 2018 IMC – Section [A]107.2.1 Information on construction documents.

Provide Equipment Schedule showing all existing systems to be used/retained. 2018 IMC – Section [A]107.2.1 Information on construction documents.

If applicable for existing systems provide smoke detectors as per 2018 IMC Section 606

Provide ventilation for all service bays 2018 IMC TABLE 403.3.1.1 MINIMUM VENTILATION RATES




Electrical(E) Reviewer
Ron Ross
rross@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 9/19/2023 6:42:15 PM
Electrical Review of United Rentals
By: Ron Ross PE
Comment only: Sheets not submitted in order shown on sheet index.

SE-101 Site Lighting & Electrical Plan:

Comment only, Keynote 1’s circuits seem small for application.

Could not locate Keynote 2.

E-201a Electrical Floor Plan - Building 1:

One of the Power & Data Keynote’s E2 seem to be pointing to an interior TV, not a building sign.

Missing Keynote E10.

E-201b Electrical Floor Plans - Building 2: Could not locate Keynotes E2 and E3.



Plumbing(P) Reviewer
Perry Hendershott
phendershott@safebuilt.com
Denied
Reason:
Date Completed : 9/21/2023 11:19:41 PM
First Plumbing review:
1). Plan page P-101a needs to illustrate the sanitary, venting, water piping configurations for the added drinking fountains & emergency eyewash stations. -IPC 106.3.1, 604.3, 901.2.1

2). Plan page P-101b needs to illustrate the sanitary, venting, water piping configurations for the added drinking fountains, sk-1 sink, urinal, second floor rest room, & emergency eyewash station. -IPC 106.3.1, 604.3, 901.2.1

3). Plan page P-101c oil interceptor needs to be vented -IPC 1003.9

4). Pressure washer water connection needs backflow protection. on plan page P-101a -IPC 608.1

5). Add oil interceptor sizing calculations to plan page P-101c -IPC 1003.4.2.2

6). Lavatories on plan page P-001 need ASSE 1070 mixing valves -IPC 419.5

7).Plumbing plans need to include complete piping illustrations -IPC 106.3.1
09/29/2023 Site Zoning REQUIRES RESUBMIT MASTER SET LOCATED AT: TC-COM-0923-02153 (4995 N CASA GRANDE HY TUCSON, AZ 85743) Bldg 1 & 3 (Outbuilding), Studio Session 394-308-094 WITH REVIEW NOTES TO BE COPIED ON TC-COM-0923-02259 (4985 N CASA GRANDE HY TUCSON, AZ 85743)


ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-COM-0923-02153 – TD-DEV-0923-00388
4995 N. Casa Garnde Hy. – I-1/I-2
Tenant fit-out of a new United Rentals business - BLDG 1 & BLDG 3 (1st Review)

TRANSMITTAL: September 22, 2023

Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in I-1& I-2 Zones (UDC 4.7.29). Contractor's Equipment Rental is an allowed use in the zone, subject to Use Specific Standard 4.9.13.Q.

1. As development package (DP) TD-DEV-0923-00388 has not yet been accepted for review Zoning cannot review the building plans for compliance with the DP. Until the DP is reviewed and approved Zoning cannot approve this building plan set.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
09/26/2023 Fire New Construction REVIEW COMPLETED MASTER SET LOCATED AT: TC-COM-0923-02153 (4995 N CASA GRANDE HY TUCSON, AZ 85743) Bldg 1 & 3 (Outbuilding), Studio Session 394-308-094 WITH REVIEW NOTES TO BE COPIED ON TC-COM-0923-02259 (4985 N CASA GRANDE HY TUCSON, AZ 85743)
09/07/2023 PDSD Application Completeness Express REVIEW COMPLETED