Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: TC-COM-0923-02126
Parcel: 10821018Y

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.3

Permit Number - TC-COM-0923-02126
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/09/2024 Commercial Electrical APPROVED
01/11/2024 Commercial Mechanical APPROVED
01/11/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/11/2024 Commercial Plumbing REQUIRES RESUBMIT The specified faucet provides either 0.5 GPM flow without a timer or a timed flow for 7.5 seconds. Specify a faucet that dispenses a maximum of 0.25 gallons per metering cycle and a delivery cycle that will last for at least 10-seconds. [Initial comment: Provide a metering faucet for the lavatory, dispensing a maximum of 0.25 gallons per metering cycle. Verify that the faucet cycle will last for at least 10-seconds. Reference: Section 419.6, IPC 2018, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09.]
12/19/2023 PDSD Application Completeness Express REVIEW COMPLETED