Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-0923-02126
Parcel: 10821018Y

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.3

Permit Number - TC-COM-0923-02126
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/09/2024 Commercial Electrical APPROVED
01/11/2024 Commercial Mechanical APPROVED
01/11/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/11/2024 Commercial Plumbing REQUIRES RESUBMIT The specified faucet provides either 0.5 GPM flow without a timer or a timed flow for 7.5 seconds. Specify a faucet that dispenses a maximum of 0.25 gallons per metering cycle and a delivery cycle that will last for at least 10-seconds. [Initial comment: Provide a metering faucet for the lavatory, dispensing a maximum of 0.25 gallons per metering cycle. Verify that the faucet cycle will last for at least 10-seconds. Reference: Section 419.6, IPC 2018, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09.]
12/19/2023 PDSD Application Completeness Express REVIEW COMPLETED