Permit Number: TC-COM-0826-01419
Parcel: 12002043A

Address:
3813 S 16TH AV

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0826-01419
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/14/2026 Site Engineering Standard APPROVED
09/28/2026 Commercial Mechanical Standard NOT REQUIRED
09/28/2026 Commercial Plumbing Standard NOT REQUIRED
09/15/2026 Outdoor Lighting Standard NOT REQUIRED No modification to the outdoor lighting.
09/28/2026 Water - PDSD Standard NOT REQUIRED
09/30/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/24/2026 Addressing Validation REQUIRES RESUBMIT If you have any questions, please contact cdrc@tucsonaz.gov

The address listed on the permit and the plans is a City owned property. The address of the store where the work is occurring is 3813 S 16TH AV, and the parcel number for that address is 12002043A. Please submit a change of address to correct permit address to 3813 S 16TH AV, and resubmit plans with updated address.

Instructions can be found here to request change of address: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf

Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf
09/28/2026 Commercial Building Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0826-01419
ADDRESS/PARCEL: (761 W AJO WY TUCSON, AZ 85713)
Submit your revised drawings along with a ***detailed response letter***, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed.

Should you have any questions about these Commercial Building comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976.

COMMENTS:
1. INCLOMPLETE SET OF DRAWINGS.
a. Please remove the note behind every seal on EVERY SHEET of drawings. Remove: “PRELIMINARY DRAWINGS DESIGN DEVELOPMENT NOT FOR CONSTRUCTION”.
b. Please submit detail drawings done by an Arizona licensed professionals. Have each Architect/Engineers seal/sign/date their specific drawings.
c. Please submit complete set of drawings showing how all of the following are installed.
i. (3) NEW GILBARCO 3+0 DISPENSERS
ii. (2) NEW GILBARCO 3+1 DISPENSERS FOR DSL
iii. (1) 10' DIA. 20K GAL. DW FIBERGLASS UST FOR REGULAR UNLEADED (RUL)
iv. (1) 10' DIA. 20K GAL. SPLIT DW FIBERGLASS UST FOR 12K DIESEL (DSL)
v. AND 8K PREMIUM UNLEADED (PUL)
vi. (2) 2.0 hp VARIABLE SPEED STP's FOR RUL AND PUL
vii. (1) 1.5 hp FIXED SPEED STP FOR DSL
viii. (3) ATG's (1 PER STP SUMP)
ix. (3) PRODUCT FILL BUCKETS (1 FOR EACH UST)
x. 1.5" FLEX PIPING IN 4" CHASE PIPING FOR RUL, PUL, AND DSL
xi. 2" SW FRP VENT PIPING (UST's TO REMOTE VENT SUMP)
xii. (1) NEW OPW VENT BOX FOR RUL, PUL, AND DSL
xiii. (5) NEW CUSTOM ISLAND FORMS AT EACH DISPENSER
xiv. NEW VEEDER ROOT TLS-450 PLUS SITE MONITOR CONSOLENEW SET OF CURRENT CONDITION DRAWINGS
2. Please resubmit.
09/18/2026 Commercial Electrical Standard REQUIRES RESUBMIT Commercial Electrical Review TC-COM-0826-01419 (761 W AJO WY TUCSON, AZ 85713)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

1. Remove the “Preliminary, not for construction” stamp from the plans. Provide plans approved for construction.
2. Show any electrical reconnections or work in compliance with NEC 514.
09/24/2026 Site Zoning Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM:
Jeffrey W. Cassidy, Planner I
Planning & Development Services Department – Current Zoning Review Section, Commercial

PROJECT:
TC-COM-0826-01419 – Commercial – Replacement of underground storage tanks, fuel product piping & fuel dispensers
761 W AJO WY TUCSON, AZ 85713 (C-2 Zoning)
Commercial Building Plan Review – 1st Review

TRANSMITTAL DATE:
September 24, 2026

1. COMMENT: As it was determined that no development package will be required, remove reference to TD-DEV-####-##### on all five sheets.

2. COMMENT: The 761 West Ajo Wy address on the drawing set is on the City of Tucson’s property, parcel 120-02-045A. The address will need to be for parcel 120-02-043A (3813 S 16TH Av. Tucson, AZ 85714). Update permit and drawing set to reflect correct address.

3. COMMENT: As a result of Comment #2, update legal description to NATIONAL CITY ANNEX N126' W40' LOT 11 EXC PTN SE COR & N126' LOT 12 EXC S34'.

4. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:

5. COMMENT: Corrected commercial building permit.

6. COMMENT: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments.

To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home .

Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf

If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code .
09/30/2026 Fire New Construction Standard REVIEW COMPLETED -Separate permits required for installation/modification of:
*Any fueling equipment (dispensers, tanks, piping, etc.)
*Contact Inspector Jesus Silva for required TFD permits and fueling system inspections.
Jesus.Silva@tucsonaz.gov
5208377094
5204199177
09/04/2026 PDSD Application Completeness Express REVIEW COMPLETED