Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0826-01414
Parcel: 117030790

Address:
835 N 6TH AV

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.2

Permit Number - TC-COM-0826-01414
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/08/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/08/2026 Commercial Electrical Express REQUIRES RESUBMIT 2nd review 10/08/2026 The previous comments were not addressed. Please see the below comments by the Electrical plan Examiner. Please provide prepared, sealed, signed, and dated by a registered design professional. And provide all the information requested in the original comment.

(Original Comment)Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. This projectCommercial Electrical Review TC-COM-0826-01414 (835 N 6TH AV TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/checklists/commercial_submittal_requirements_july2023.pdf 2. Provide Service Surge Protection per NEC 230.67(D). All downstream dwelling units require surge protection when replacing the service equipment. 3. Provide an electrical riser diagram, NEC 230.9. Include underground service entrance conductors/conduit. a. Show each meter and address/unit associated with each meter. b. Show bus bar or equipment rating and AIC ratings of the new equipment. c. Provide sizing and other info as needed to verify code compliance. 4. Provide Fault Current Analysis and show new equipment AIC rating sufficient to withstand the calculated Fault Current. Provide Available Fault Current calculations from TEP transformers to all new equipment, 2017 NEC 110.24. 5. Show new Panel’s and other new equipment with AIC ratings greater than or equal to the Available Fault Currents calculated, 2017 NEC 110.10. 6. Notate the grounding and bonding method, including water line bonding, NEC 250.20(B), 250.24, 250.30(A)(1).
Corrections (0)
10/06/2026 PDSD Application Completeness Express REVIEW COMPLETED