Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL REVISION v.1
Permit Number - TC-COM-0826-01412
Review Name: COMMERCIAL REVIEW - FULL REVISION v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/17/2026 | Commercial Building Standard | APPROVED | |||
| 11/17/2026 | Commercial Electrical Standard | APPROVED | |||
| 11/17/2026 | Commercial Mechanical Standard | APPROVED | |||
| 11/19/2026 | Water - PDSD Standard | APPROVED | |||
| 11/19/2026 | Commercial Post Review Express | PENDING ASSIGNMENT | |||
| 11/17/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | November 17, 2026 1st Review Intertech Architectural Interiors Attn: Wayne E Swan Jr. 6089 E Grant Rd. Tucson, AZ. 85712 Re: ARTO-Phase 1 Tenant Improvement (Revisions) City of Tucson Permit Number: TC-COM-0826-01412 Stantec Project Number: 185215066 Stantec File Number: TUC-26-064 Plan review for the project referenced above has been completed. This letter reflects comments to be addressed. PLEASE send all responses to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms F-2 II-B 127,000 100 Yes Yes Separate Permits: Automatic fire sprinklers and fire alarm. Deferred Submittals: None. Special Inspections: Concrete, epoxy and expansion anchors, structural steel, high-strength bolts, and field welding. ARCHITECTURAL COMMENTS There are no comments. STRUCTURAL COMMENTS There are no comments. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS Sheets P1.2, P2.2, and P4 1. The architectural drawings have been modified. The design of the men’s restroom has changed, eliminating two of the toilets and replacing the toilets with urinals; however the plumbing drawings have not been revised to coordinate with this change. Please modify the plumbing drawings to match the new design, including updating the plans, the plumbing fixture schedule and specifications. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Joel Svoboda, RA Senior Associate 520-545-7415 joel.svoboda@stantec.com |
||
| 11/18/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 10/27/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |