Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0826-01412
Parcel: 13205015H

Address:
3430 E 36TH ST

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL REVISION v.1

Permit Number - TC-COM-0826-01412
Review Name: COMMERCIAL REVIEW - FULL REVISION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/17/2026 Commercial Building Standard APPROVED
11/17/2026 Commercial Electrical Standard APPROVED
11/17/2026 Commercial Mechanical Standard APPROVED
11/19/2026 Water - PDSD Standard APPROVED
11/19/2026 Commercial Post Review Express PENDING ASSIGNMENT
11/17/2026 Commercial Plumbing Standard REQUIRES RESUBMIT November 17, 2026
1st Review

Intertech Architectural Interiors
Attn: Wayne E Swan Jr.
6089 E Grant Rd.
Tucson, AZ. 85712

Re: ARTO-Phase 1
Tenant Improvement (Revisions)

City of Tucson Permit Number: TC-COM-0826-01412
Stantec Project Number: 185215066
Stantec File Number: TUC-26-064

Plan review for the project referenced above has been completed. This letter reflects comments to be addressed. PLEASE send all responses to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken.

The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

Occupancy
Group Construction
Type Area
(Square feet) Occupant
Load Automatic
Fire Sprinklers Fire
Alarms
F-2 II-B 127,000 100 Yes Yes
Separate Permits: Automatic fire sprinklers and fire alarm.
Deferred Submittals: None.
Special Inspections: Concrete, epoxy and expansion anchors, structural steel, high-strength bolts, and field welding.

ARCHITECTURAL COMMENTS

There are no comments.

STRUCTURAL COMMENTS

There are no comments.

MECHANICAL COMMENTS

There are no comments.

PLUMBING COMMENTS

Sheets P1.2, P2.2, and P4

1. The architectural drawings have been modified. The design of the men’s restroom has changed, eliminating two of the toilets and replacing the toilets with urinals; however the plumbing drawings have not been revised to coordinate with this change. Please modify the plumbing drawings to match the new design, including updating the plans, the plumbing fixture schedule and specifications.

ELECTRICAL COMMENTS

There are no comments.


Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline.

Plans reviewed by:
Joel Svoboda, RA
Senior Associate
520-545-7415
joel.svoboda@stantec.com
11/18/2026 Fire New Construction Standard REVIEW COMPLETED
10/27/2026 PDSD Application Completeness Express REVIEW COMPLETED