Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0826-01383
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/10/2026 | Commercial Building | APPROVED | |||
| 09/03/2026 | Commercial Electrical | APPROVED | |||
| 09/11/2026 | Water - PDSD | APPROVED | |||
| 09/01/2026 | Site Engineering | NOT REQUIRED | |||
| 09/11/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/27/2026 | Addressing Validation | REQUIRES RESUBMIT | If you have any questions, please contact cdrc@tucsonaz.gov Once this initial review is complete please resubmit the construction documents with full project address, including unit number, on all pages. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf |
||
| 09/11/2026 | Commercial Mechanical | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0826-01383 ADDRESS/PARCEL: 1570 E TUCSON MARKETPLACE BL Unit:UNIT 108 TUCSON, AZ 85713 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov COMMENTS: 1. Recirculation of air from nail salon spaces is prohibited. If the air is recirculated throughout the tenant space (to the waiting/reception areas, corridor, etc), please classify the entire space as a nail salon and revise the outdoor air and exhaust calculations accordingly. Reference: Section 403.3.1.1 and Table 403.3.1.1, IMC 2024. 2. Please provide details of the manicure/pedicure stations showing the exhaust inlet locations. Exhaust inlets shall be located no more than 12 inches horizontally and vertically from the point of chemical application. Reference: Section 502.20 and Table 403.3.1.1, Note h, IMC 2024. |
||
| 09/11/2026 | Commercial Plumbing | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0826-01383 ADDRESS/PARCEL: 1570 E TUCSON MARKETPLACE BL Unit:UNIT 108 TUCSON, AZ 85713 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov COMMENTS: 1. P-5 on the partial water isometric should be P-4, the pedicure chair. Please correct. Reference: Section 107.2.1, IBC 2024. 2. Please demonstrate that the maximum water temperature delivered to the pedicure chairs will not exceed 120°F. Show the location of the temperature-limiting device on the plans and provide manufacturer specifications. Reference: Section 423.3, IPC 2024. |
||
| 09/11/2026 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Jeffrey W. Cassidy, Planner I Planning & Development Services Department – Current Zoning Review Section, Commercial PROJECT: TC-COM-0826-01383 – Commercial – Tenant Improvement for Posh Nail Spa 1570 E TUCSON MARKETPLACE BL Unit 108 TUCSON, AZ 85713 (PAD-15 Zoning) Commercial Building Review – 1st Review TRANSMITTAL DATE: September 11, 2026 1. COMMENT: Update zoning classification from PAD to PAD-15 on the A1 sheet. 2. COMMENT: Add the Zoning Use to the A1 sheet sheet: Commercial Services Use – Personal Services subject to use specific standards 4.9.4.T.1 and 4.9.13.O. 3. COMMENT: Indicate the vehicle parking required and provided per PAD-15 document, page 66. 4. COMMENT: Indicate the bicycle parking required and provided per PAD-15 document, page 66 and LUC page 235 and page 237. 5. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: 6. COMMENT: Updated building permit. 7. COMMENT: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home . Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code . |
||
| 09/10/2026 | Fire New Construction | REVIEW COMPLETED | |||
| 08/27/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |