Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.2

Permit Number - TC-COM-0826-01382
Review Name: COMMERCIAL REVIEW - LIMITED v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/02/2026 Commercial Building APPROVED
10/05/2026 Site Zoning APPROVED
10/05/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/05/2026 Commercial Mechanical REQUIRES RESUBMIT The City of Tucson did not adopt ASHRAE Standard 62.1 for ventilation calculations and the 2024 IMC only references the ASHRAE Standard for the purpose of calculating the system ventilation efficiency (Ev). Provide calculations to show that the ventilation system is sized in accordance with Section 401.2, IMC 2024.

If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov.
10/05/2026 Commercial Plumbing REQUIRES RESUBMIT Show how tepid water is provided to the lavatory. Reference: Sections 303.4, 419.5, and 607.1.2, IPC 2024, and Section C404.5, IECC 2024.
If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov.
10/05/2026 Fire New Construction REVIEW COMPLETED
09/21/2026 PDSD Application Completeness Express REVIEW COMPLETED