Permit Review Detail
Review Status: In Review
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0826-01380
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/13/2026 | Commercial Building Standard | APPROVED | |||
| 09/24/2026 | Outdoor Lighting Standard | NOT REQUIRED | |||
| 09/28/2026 | Site Engineering Standard | NOT REQUIRED | |||
| N/A | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| N/A | Fire New Construction Standard | PENDING ASSIGNMENT | |||
| 09/29/2026 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0826-01380 (8080 S HOUGHTON RD TUCSON, AZ 85747) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Provide manufacturer's UL 3741 installations instructions and list of UL 3741 compatible equipment to show compliance with NEC 690.12. 2. Provide Fault Current Analysis and show new equipment AIC rating sufficient to withstand the calculated Fault Current. Provide Available Fault Current calculations from TEP transformers to all new equipment, 2017 NEC 110.24. 3. Show new Panel’s and other new equipment with AIC ratings greater than or equal to the Available Fault Currents calculated, 2017 NEC 110.10. 4. Wrong sheet reference on line diagram. Reference sheet E202, raceways from the inverters to the two solar panelboards references the wrong sheet. Please correct. 5. Incorrect EGC size per NEC 250.122, and Table 250.122. Reference sheet E202, Raceway IDs AC1.10 and AC1.11. Provide EGC per Table 250.122. 6. Reference sheet E400, Table C1, Raceway Names, AC1.10 & AC1.11, conductor sizing does not match line diagram. calculations are incorrect. 7. A signature and date are required as part of the Registrant Seal (Electrical). Section R4-30-304 of the Rules of the Arizona State Board of Technical Registration states that in addition to signing the seal, the registrant shall include the date the document was signed. The EOR seal is missing the date signed. |
||
| 10/12/2026 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Jeffrey W. Cassidy, Planner I Planning & Development Services Department – Current Zoning Review Section, Commercial PROJECT: TC-COM-0826-01380 – Commercial – Solar PV at Existing Fry's 8080 S HOUGHTON RD TUCSON, AZ 85747 (C-2 Zoning) Commercial Building Plan Review – 1st Review TRANSMITTAL DATE: October 12, 2026 1. COMMENT: Update the sheet index to a) account for all the drawings provided intended for review and permitting and/or b) provide missing sheets; E201, E500, E801 and E802 2. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: 3. COMMENT: Corrected commercial building permit. 4. COMMENT: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home . Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code . |
||
| 09/24/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |