Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0826-01344
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/10/2026 | Commercial Building | APPROVED | |||
| 09/08/2026 | Site Zoning | APPROVED | |||
| 09/09/2026 | Water - PDSD | APPROVED | |||
| 09/03/2026 | Site Engineering | NOT REQUIRED | |||
| 09/10/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/01/2026 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0826-01344 (631 W MIRACLE MILE TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. provide GFCI protection for all receptacles and appliances, including the washer, dryer and W/H, in the bathroom/laundry area per NEC 210.8(B)(14) & 210.8(D)(11). May require GFCI breakers or other approved means to maintain ready access to GFCI devices, 210.8. 2. Correct the circuit designation on the electrical plan for the washer and water heater receptacles. Washer should be 14 and Water Heater should be 9. Note: 22 does not exist within the panel schedule. |
||
| 09/09/2026 | Commercial Mechanical | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0826-01344 ADDRESS/PARCEL: 631 W MIRACLE MILE TUCSON, AZ 85705 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov. COMMENTS: 1. Please clarify the scope of work regarding any proposed mechanical or plumbing changes. Reference: Section 107.2.1, IBC 2024. 2. Please identify and show any existing mechanical equipment serving this space. Reference: Section 107.2.1, IBC 2024. Also, show how ventilation will be provided for this space, as Demolition Plan Note 2 indicates the existing window unit will be removed. Reference: Section 403.3.3.1, IMC 2024. |
||
| 09/09/2026 | Commercial Plumbing | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0826-01344 ADDRESS/PARCEL: 631 W MIRACLE MILE TUCSON, AZ 85705 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov. COMMENTS: 1. There is a note to remove and cap existing sewer and water lines, but the locations of these lines are not identified on the plans. Please show the existing sewer and water lines to be removed and capped. Reference: Section 107.2.1, IBC 2024. 2. A water heater appears to be located near the washer and dryer. Please clarify whether the water heater is existing, and whether it is gas-fired or electric. |
||
| 09/08/2026 | Fire New Construction | REVIEW COMPLETED | |||
| 08/25/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |