Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0826-01311
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/15/2026 | Commercial Electrical | APPROVED | |||
| 09/15/2026 | Commercial Plumbing | APPROVED | |||
| 09/03/2026 | Site Zoning | APPROVED | |||
| 09/03/2026 | Water - PDSD | APPROVED | |||
| 09/15/2026 | Commercial Mechanical | NOT REQUIRED | |||
| 08/21/2026 | Site Engineering | NOT REQUIRED | |||
| 09/15/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/15/2026 | Commercial Building | REQUIRES RESUBMIT | September 14, 2026 1st Review Seaver Franks JaMia Dees 2552 N. Alvernon Way Tucson, Arizona 85712 Re: TUCSON FEDERAL CREDIT UNION- EL RIO TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0826-01311 Stantec Project Number: 185215066 Stantec File Number: TUC-26-051 Plan review for the project referenced above has been completed. This letter reflects comments to be addressed. PLEASE send all responses to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, plumbing, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 6,00 190 Yes No Separate Permits: Automatic fire sprinklers Deferred Submittals: None. Special Inspections: None. ARCHITECTURAL COMMENTS Sheet A0.0 1. Please indicate that the automatic fire sprinkler system [2024 IBC Sec. 903] is to be provided as part of this project and is to be submitted as a separate permit (not a deferred submittal). Currently it shows as a deferred submittal. Sheet A4.0 1. The vertical grab bars shown in Detail 6 are incorrectly location; coordinate their placement with the information found in Detail 3 on Seet A5.0. 2. The water closet levers shown on Details 2 and 5 in the accessible toilet stalls must be located towards the open side of the water closet per ICC/ANSI A117.1-2017 Sec. 604.6. Sheet A4.2 1. Detail 4 shows that neither of the microwaves in the breakroom is within the reach ranges required by ICC/ANSI A117.1-2017 Sec. 804.5, 309.3, and 308. The bottom of both microwaves are at 58 inches above the floor; at least one must be within required reach ranges. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Joel Svoboda, RA Senior Associate 520-545-7415 joel.svoboda@stantec.com |
||
| 09/01/2026 | Fire New Construction | REVIEW COMPLETED | |||
| 08/20/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |