Permit Number: TC-COM-0826-01311
Parcel: 115211580

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0826-01311
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/15/2026 Commercial Electrical APPROVED
09/15/2026 Commercial Plumbing APPROVED
09/03/2026 Site Zoning APPROVED
09/03/2026 Water - PDSD APPROVED
09/15/2026 Commercial Mechanical NOT REQUIRED
08/21/2026 Site Engineering NOT REQUIRED
09/15/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/15/2026 Commercial Building REQUIRES RESUBMIT September 14, 2026
1st Review

Seaver Franks
JaMia Dees
2552 N. Alvernon Way
Tucson, Arizona 85712

Re: TUCSON FEDERAL CREDIT UNION- EL RIO
TENANT IMPROVEMENT

City of Tucson Permit Number: TC-COM-0826-01311
Stantec Project Number: 185215066
Stantec File Number: TUC-26-051

Plan review for the project referenced above has been completed. This letter reflects comments to be addressed. PLEASE send all responses to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken.

The scope of this review covers the architectural, plumbing, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

Occupancy
Group Construction
Type Area
(Square feet) Occupant
Load Automatic
Fire Sprinklers Fire
Alarms
B V-B 6,00 190 Yes No
Separate Permits: Automatic fire sprinklers
Deferred Submittals: None.
Special Inspections: None.

ARCHITECTURAL COMMENTS

Sheet A0.0

1. Please indicate that the automatic fire sprinkler system [2024 IBC Sec. 903] is to be provided as part of this project and is to be submitted as a separate permit (not a deferred submittal). Currently it shows as a deferred submittal.
 
Sheet A4.0

1. The vertical grab bars shown in Detail 6 are incorrectly location; coordinate their placement with the information found in Detail 3 on Seet A5.0.

2. The water closet levers shown on Details 2 and 5 in the accessible toilet stalls must be located towards the open side of the water closet per ICC/ANSI A117.1-2017 Sec. 604.6.

Sheet A4.2

1. Detail 4 shows that neither of the microwaves in the breakroom is within the reach ranges required by ICC/ANSI A117.1-2017 Sec. 804.5, 309.3, and 308. The bottom of both microwaves are at 58 inches above the floor; at least one must be within required reach ranges.

PLUMBING COMMENTS

There are no comments.

ELECTRICAL COMMENTS

There are no comments.